The technical requirements for trails include specific provisions for the surface, clear tread width, passing spaces, tread obstacles, openings, running slope, cross slope, resting intervals...
Search Results "Slope Meter"
-
Technical Requirements [1017]
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and ¾ inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)....
-
Passing Spaces on Trails
Where the clear tread width of a trail is less than 60 inches (1,525 millimeters), provide passing spaces at least every 1,000 feet (300 meters) and at the end of any segment of trail that...
-
1132A.4.1, Item 2
Thresholds with a change in height between ¼ inch (6.35 mm) and 3/4 inch (19.05 mm) shall be beveled with a slope no greater than 1 unit vertical in 2 units horizontal (50-percent slope)...
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
-
11B-404.2.5 Thresholds
[2010 ADA Standards] EXCEPTION: Existing or altered thresholds ¾ inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required...
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)
Parking: The surface slope of the designated accessible van space exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4)....
-
What other surface considerations affect wheelchair travel?
In addition to slip resistance requirements, wheelchair users are affected by the rolling resistance of the surface of the floor and--on exterior surfaces--by cross slope....
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
1017.10 Trailhead Signs
Typical and maximum running slope; and 5. Typical and maximum cross slope....
-
1017.10 Trailhead Signs
Typical and maximum running slope; and 5. Typical and maximum cross slope....
-
Where do I measure for a handrail extension?
See Dimensions D in the attached Sketches B and C. 505.10.3 Bottom Extension at Stairs At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for...
-
Attachment I
All spaces and access aisles for persons with disabilities shall be flat and level, with slopes and cross-slopes not exceeding 1:50 in all directions, and their surfaces shall be firm, stable...
-
1014.3 Floor
This section requires the floor surface within camp shelters to be firm and stable and to slope not steeper than 1:48 in any direction....
-
11B-403.7 Continuous gradient
The slope of the resting area in all directions shall be 1:48 maximum. ETA Editor's Note CBC requirement 11B-403.7 is not present in the 2010 ADA Standards....
-
11B-403.7 Continuous gradient
The slope of the resting area in all directions shall be 1:48 maximum. ETA Editor's Note CBC requirement 11B-403.7 is not present in the 2010 ADA Standards....
-
1010.1.6 Thresholds
Raised thresholds and floor level changes greater than ¼ inch (6.4 mm) at doorways shall be beveled with a slope not greater than one unit vertical in two units horizontal (50-percent slope...