All wall drain No-Flush™ urinal models install like flushed urinals to the drain line via a gasket and flange. No adaptors needed!...
Search Results "Shower Drain"
Commonly Searched Documents
- Waterless Co. Urinal Borrego 2103
- Just Manufacturing Undermount Group Oval Lavatory with Overflow
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
Permanent seats shall be positioned at the head end of the bathtub.14 Nineteen-inch high shower compartment seats are accessible: 610.3 Shower Compartment Seats....
-
11B-809.10.5.1 Clear floor space
clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or bathtub-shower...
- Kohler Dynametric® 60" x 32" Alcove Bath
-
Transfer Sides (M301.2.3 and M302.2.3)
The 2004 ADA and ABA Accessibility Guidelines provide a gap of 3 inches between the edge of a shower seat and the shower compartment entry, and the gap does not appear to interfere with...
-
1134A.5 Bathtubs
There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to provide for the maneuvering...
-
Birthing Room Bath Tub Accessibility
Where provided, one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 11B-603 (Toilet and Bathing Rooms) through 11B-610 (Seats)....
-
1134A.5, Item 1
There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to provide for the maneuvering...
-
[F] 907.5.2.3.1 Public and common use areas
alarm notification appliances shall be provided in public use areas and common use areas, including but not limited to: Sanitary facilities including restrooms, bathrooms and shower...
-
1134A.5, Item 1
There shall be a minimum clear floor space 48 inches parallel by 30 inches perpendicular (1219 mm by 762 mm) to the side of a bathtub or bathtub-shower combination to provide for the maneuvering...
- Just Manufacturing Oval Lavatory Group Drop-in Sink with Overflow
- Stabilizer Solutions StaLok Stabilizer Joint Sand
-
Other Features in Progress
Moveable stairs for transfer into the spa from a wheelchair Grab bars around the roll-in shower in the den bath Fold-down blockers on all sliding doors for increased security...
-
11B-604.5.1 Side wall
A bath station that can be activated by a patient lying on the floor shall be provided at each room containing a patient water closet, bathtub, sitz bath, or shower stall....
-
Methodology and Data Analysis
The information collected included the location of and approach to water closets, transfer and roll-in showers, and bathtubs; space requirements at fixtures; support and transfer devices...
- Kohler Elevance Rising Wall Alcove Bath
- American Standard Green Tea Deck-Mount Tub Filler
- Rebuilding Together Harrisonburg-Rockingham County - Harrisonburg, VA
- Guardian Barrier-Free Safety Station with WideArea™ Eye/Face Wash GBF1909PCC
-
9.2.2(6)
., one with a water closet, a lavatory, and a bathtub or shower). (f) if only half baths are provided, at least one half bath. (g) carports, garages or parking spaces....
-
Space Allowance and Reach Ranges [4.2]
For example, the specified height of toilets and shower seats (17-19 inches) approximates the standard seat height of manual wheelchairs to facilitate transfer....
-
11B-604.5.1 Side wall
A bath station that can be activated by a patient lying on the floor shall be provided at each room containing a patient water closet, bathtub, sitz bath, or shower stall....
-
d. Unobstructed Transfer
The Access Board explained that “[t]he 2004 ADA and ABA Accessibility Guidelines provide a gap of 3 inches between the edge of the shower seat and the shower compartment entry, and the gap...