Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section 11B-703.3....
Search Results "Operable Part (Control)"
-
11B-407.4.7.1.1 Type
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section 11B-703.3....
-
11B-707.6.1 Input controls
11B-707.6.1 Input controls. At least one tactilely discernible input control shall be provided for each function....
-
§27.71(f)
(f) Contracts or leases between carriers and airport operators concerning the use of airport facilities shall set forth the respective responsibilities of the parties for the provision of...
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
Specifications for Alternate Roll-in Shower Controls
Specifications for controls, faucets, and shower spray units for alternate roll-in showers are provided in section 608.5.3....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
- Simple Pump Company ADA 100 Simple Water Pump
- Wikk Industries Inc. Push Plate PART# BPS SM PRP36 CL (628)
-
§27.71(g)
(g) If an airport operator who receives Federal financial assistance for an existing airport facility has not already done so, the recipient shall submit a transition plan meeting the requirements...
-
Section 810.2.2
The Department is adding language from former §37.9 (c) of this part, which provides that “Public entities shall ensure the construction of bus boarding and alighting areas comply with 810.2.2...
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2....
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2....
- Door King Inc. Proximity Card Readers
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.
-
11B-407.4.6.2.1 Size and shape
Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch (0.8 mm) above the surrounding...
-
407.4.6.2.1 Size
Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension.
-
407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.