The height of the transfer platform shall comply with 1009.4.2....
Search Results "Height Adjustable"
-
1009.5.3 Height
-
1009.5.3 Height
The height of the transfer platform shall comply with 1009.4.2....
-
227 and 904 Sales and Service
[See subsections ...]
-
Attachment I
height of 36 in close proximity to the main counter; or provide equivalent facilitation. ...
-
1008.3.2.2 Height
1008.3.2.2 Height. Each transfer step shall be 8 inches (205 mm) high maximum....
-
811.3 Height
811.3 Height. Storage elements shall comply with at least one of the reach ranges specified in 308....
-
309.3 Height
309.3 Height. Operable parts shall be placed within one or more of the reach ranges specified in 308....
-
Platform Height
Platform Height Transfer platforms must be between 16 and 19 inches high, measured from the deck....
-
R403.3 Height
R403.3 Height. Operable parts shall be placed within one or more of the reach ranges specified in R406....
-
407.4.6.4.1 Height
407.4.6.4.1 Height. Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
-
Maneuvering Space, Adjustable Cabinetry, Fixtures and Plumbing
A number of commenters from the disability community stated that it was important that the Guidelines for both kitchens and bathrooms specify a five-foot turning radius; adjustable cabinetry...
-
1009.4.2 Height
The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
-
1013.3 Height
1013.3 Height. Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: 1. From the adjacent walking surfaces; 2. ...
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
M303.2.4.1.2 Height
Between 9 inches (230 mm) and 27 inches (685 mm) above the floor, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for every 6 inches (150 mm) in height...
-
Height Requirements
The proposed rule included an exception from the height requirements in 309.3 for special equipment and electrical and communications systems receptacles....
-
407.3.3.1 Height
407.3.3.1 Height....
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be...
-
11B-606.2 Clear floor space
11B-606.2 Clear floor space. A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be...
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be...