Advisory 11B-704.4.1 Height....
Search Results "Height Adjustable"
Commonly Searched Documents
-
11B-704.4.1 Height
-
11B-411.3.3.1 Height
The height of the reopening device shall comply with Section 11B-407.3.3.1....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
11B-411.3.3.1 Height
The height of the reopening device shall comply with Section 11B-407.3.3.1....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
11B-1009.5.3 Height
The height of the transfer platform shall comply with Section 11B-1009.4.2....
-
11B-411.3.3.1 Height
The height of the reopening device shall comply with Section 11B-407.3.3.1....
-
Guest Rooms
Bed heights for accessible rooms should be between 17-23 inches above the floor Do not have border frame which prevents the wheelchair from being directly next to the mattress....
-
II. Recommendations of Diagnostic Imaging Equipment Manufacturers on Transfer Surface Low Height
We believe the addition of the adjustability requirement delivers by far a larger increase in access than having a single minimum height of 17 inches....
-
[F] 907.4.2.2 Height
[F] 907.4.2.2 Height. ...
-
B. The ADA Standards for Accessible Design
Thus, the relevant 2010 Standards address only limited aspects of sales and service counters: the counter's height and length and the required clear floor space based on the available approaches...
-
5.8.2.5 Toe Height Recommendation
recommended that the toe height be set to 18 inches (when the breast platform is at the 34 inch height discussed above)....
-
5.8.3.1 Breast Platform Height
5.8.3.1 Breast Platform Height. The height of the top of the breast platform should be decreased to 26 inches above the floor....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1. A parallel approach...
-
606.2 Clear Floor Space
606.2 Clear Floor Space. A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
SEAT HEIGHT MEASUREMENT DETAIL
SEAT HEIGHT MEASUREMENT DETAIL Regardless of measurement technique used, the height is measured at the highest point of the seat, inclusive of bolsters, with the foam in an uncompressed...
-
M303.2.4.2.2 Height
Between 9 inches (230 mm) and 27 inches (685 mm) above the floor, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for every 6 inches (150 mm) in height...
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
11B-1009.4.2 Height
The height of the transfer wall shall be 16 inches (406 mm) minimum and 19 inches (483 mm) maximum measured from the deck....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be not less than 42 inches (1067 mm) and not more than 48 inches (1219 mm) measured vertically, from the floor level to the highest point...
-
Protocol C Heights Obtained
For the maximum height transfers HERL's percentile heights were slightly higher for the 25th and 75th percentiles than the NDVWSC heights....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....