11B-233.3.1.2.6.4 Test number three, unusual characteristics test
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
11B-233.3.1.2.6.2 Test number one, individual building test
It is not required by this code to provide an accessible route when the terrain of the site is such that both of the following apply: 1. The slopes of the undisturbed site...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
17.1 Q. Is it correct that only the exterior side of the main entry door of covered multifamily dwellings must meet the ANSI requirements?
The interior of the main entry door is part of the dwelling unit and only needs to meet the requirements for usable doors within the dwelling intended for user passage, i.e., at least 32...
-
3(2)
(2) Within individual dwelling units, doors intended for user passage through the unit which have a clear opening of at least 32 inches nominal width when the door is open 90 degrees, measured...
-
11B-229.1 General
Exception: Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229....
-
Thresholds at Exterior Doors/Thresholds to Balconies or Decks
In such case, the surface should be no more than 4 inches below the floor level of the interior dwelling unit, unless the local code requires a lower drop....
-
30.1 Q. Would it be acceptable to use removable base cabinets beneath a wall-hung lavatory where a parallel approach is not possible?
A. Yes. The space under and around the cabinet should be finished prior to installation. For example, the tile or other floor finish must extend under the removable base cabinet.
-
29.1 Q. Is it acceptable to design a bathroom with an in-swinging 2'10 door which can be retrofitted to swing out in order to provide the necessary clear floor space in the bathroom?
A. No. The requirements in the Guidelines must be included at the time of construction. Thus, for a bathroom, there must be sufficient maneuvering space and clear floor space so that...
-
7(2)(a)(i)
(i) Sufficient maneuvering space is provided within the bathroom for a person using a wheelchair or other mobility aid to enter and close the door, use the fixtures, reopen the door...
-
7(1)(b)
(b) Clearance between counters and all opposing base cabinets, countertops, appliances or walls is at least 40 inches.
-
7(2)(b)(ii)
(ii) Where the door swings out, a clear space is provided within the bathroom for a person using a wheelchair or other mobility aid to position the wheelchair such that the person is...
-
11B-229.1 General
Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229. 2. ...
-
E101.4 Units of Measurement (Section-by-Section Analysis)
E101.4 Units of Measurement (Section-by-Section Analysis) This section would note measurements are stated in U.S. customary and metric units and that the values stated in each system...
-
C101.4 Units of Measurement (Section-by-Section Analysis)
C101.4 Units of Measurement (Section-by-Section Analysis) This proposed section, which also has a counterpart in the proposed 508 Standards (E101.4), provides that measurements are stated...
-
1132A.1 Primary entry doors and required exit doors
., entry or exit doors which open from the covered multifamily dwelling unit into a corridor, hallway or lobby, or directly to the outside)....
-
M101.7 Units of Measurement (Section-by-Section Analysis)
In the MDE NPRM there was no explanation of the units of measurement used throughout the rule text....
-
11B-233.3.4.1 Alterations to vacated buildings
In addition, at least 2 percent of the residential dwelling units shall comply with Section 11B-809.5 _|Residential Dwelling Units with Communication Features|_....
-
11B-233.3.4.1 Alterations to vacated buildings
In addition, at least 2 percent of the residential dwelling units shall comply with Section 11B-809.5 _|Residential Dwelling Units with Communication Features|_....
-
Supplementary Information:
Accessible route into and through the dwelling unit. Requirement 5....
-
11.2 Q. Under the individual building test, at what point of the planned entrance is the measurement taken?
center of each individual doorway should be the point of measurement when measuring to an arrival point, whether the doorway is an entrance door to the building or an entrance door to a unit...
-
22.1 Q. Must the switches on range hood kitchen ventilation fans be in accessible locations?
The Fair Housing Act has no requirements for appliances in the interiors of dwelling units, or the switches that operate them....
-
11B-233.3.4.1 Alterations to vacated buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...