The clear width of beach access routes shall be 60 inches (1525 mm) minimum....
Search Results "Clear Deck Space"
Commonly Searched Documents
-
1018.4 Clear Width
-
5.1.7 Surface
The surface of the clear ground space shall be firm and stable....
-
11B-502.2 Vehicle spaces
Car and van parking spaces shall be 216 inches (5486 mm) long minimum....
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture....
-
1008.2.4 Clear Width
Accessible routes connecting play components shall provide a clear width complying with 1008.2.4....
-
1008.2.4 Clear Width
Accessible routes connecting play components shall provide a clear width complying with 1008.2.4....
-
606.2 Clear Floor Space
606.2 Clear Floor Space. A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided. EXCEPTIONS: 1....
-
4.6.3* Parking Spaces
Accessible parking spaces shall be at least 96 in (2440 mm) wide....
-
1. Accessible toilet
Accessible toilet with rear and side grab bars, clear floor space for wheelchair transfer, and an accessible flush valve....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space. ...
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADAS] 805.3 Clear Floor or Ground Space....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADA Standards] 805.3 Clear Floor or Ground Space....
-
606.2 Clear Floor Space
A clear floor space complying with 305, positioned for a forward approach, and knee and toe clearance complying with 306 shall be provided....
-
Side Approach
Side Approach The maximum reach depth for a high (54 inch maximum) reach is 10 inches, measured from the clear floor space....
-
Clear Width [1018.4]
The clear width of beach access routes must be a minimum of 60 inches to enable people using mobility devices to pass people traveling in the opposite direction without veering off the...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall....
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
Yes, as long as the necessary clear floor space shown in Figure 7(a) is provided....
-
307.5 Required Clear Width
307.5 Required Clear Width. Protruding objects shall not reduce the clear width required for accessible routes....
-
11B-813.2.1.2 Clearance
A 36 inches minimum (914 mm) width side clearance shall be provided along the entire length of one side of adult changing tables. At both ends of adult changing tables, clearance...
-
Passing Spaces on Trails
A 60-inch (1,525-millimeter) clear tread width is required for two wheelchairs to pass safely and comfortably on a trail....
-
4.6.3* PARKING SPACES
Parking spaces for disabled people shall be at least 96 in (2440 mm) wide and shall have an adjacent access aisle 60 in (1525 mm) wide minimum (see Fig. 9)....
-
11B-606.2 Clear floor space
11B-606.2 Clear floor space....
-
2.4 Patient Areas
Is there space in the waiting room for wheelchair users to sit?...