interior routes described above: ...with the exception of doors at shallow closets, do the doors to required accessible spaces, and all doors into and within guestrooms allow at least 32" clear...
Search Results "Clear"
Commonly Searched Documents
-
C. Doors
- Magnuson Group UMEA Waste Receptacles
- Landscape Forms Inc. Select Modular Steel Recycling Units
-
10.3.1(17)
EXCEPTION: Elevator cars with a clear floor area in which a 60 inch diameter circle can be inscribed may be substituted for the minimum car dimensions of 4.10, Fig. 22....
-
T502.4 Doorways with Steps on Over-the-Road Buses
On over-the-road buses, doorways with steps shall provide an opening with a clear width of 30 inches (760 mm) minimum. Exceptions: 1....
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors....
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
Distinct Viewing Locations [F246.2, 1015.2, and 1015.3]
One full, unobstructed side of the clear ground space must adjoin or overlap an ORAR or trail, as applicable, or another clear ground space....
-
Side Approach
Side Approach Clear space for a side approach is specified for units that are free-standing or built-in....
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
-
11B-407.4.1 Car dimensions
area of 18 square feet (1.67 m2) minimum and also provide an inside clear depth 54 inches (1372 mm) minimum and a clear width 48 inches (1219 mm) minimum shall be permitted...
-
11B-407.4.1 Car dimensions
area of 18 square feet (1.67 m2) minimum and also provide an inside clear depth 54 inches (1372 mm) minimum and a clear width 48 inches (1219 mm) minimum shall be permitted...
-
11B-407.4.1 Car dimensions
area of 18 square feet (1.67 m2) minimum and also provide an inside clear depth 54 inches (1372 mm) minimum and a clear width 48 inches (1219 mm) minimum shall be permitted...
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-305.3 is provided beyond the arc of the door swing.
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-305.3 is provided beyond the arc of the door swing.
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2 mentions that changes in level that do not exceed those permitted in section 303.3 are acceptable in "required clear...
-
4.2.7 Surface
The surface of the clear floor or ground space shall be firm and stable. The type of surface should be appropriate to the setting and level of development....
-
407.4.1 Car Dimensions