Constructed of painted steel and suitable for both indoors and outdoors, UMEA models can be 1, 2 or 3-compartments wide – each with selectable top inserts and corresponding front...
Search Results "Clear"
Commonly Searched Documents
- Magnuson Group UMEA Waste Receptacles
- Landscape Forms Inc. Select Modular Steel Recycling Units
-
10.3.1(17)
EXCEPTION: Elevator cars with a clear floor area in which a 60 inch diameter circle can be inscribed may be substituted for the minimum car dimensions of 4.10, Fig. 22....
-
T502.4 Doorways with Steps on Over-the-Road Buses
On over-the-road buses, doorways with steps shall provide an opening with a clear width of 30 inches (760 mm) minimum. Exceptions: 1....
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors....
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
Distinct Viewing Locations [F246.2, 1015.2, and 1015.3]
One full, unobstructed side of the clear ground space must adjoin or overlap an ORAR or trail, as applicable, or another clear ground space....
-
Side Approach
Side Approach Clear space for a side approach is specified for units that are free-standing or built-in....
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
-
807.2.3 Beds
Where beds are provided, clear floor space complying with 305 shall be provided on at least one side of the bed....
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
-
11B-807.2.3 Beds
Where beds are provided, clear floor space complying with Section 11B-305 shall be provided on at least one side of the bed....
-
11B-407.4.1 Car dimensions
area of 18 square feet (1.67 m2) minimum and also provide an inside clear depth 54 inches (1372 mm) minimum and a clear width 48 inches (1219 mm) minimum shall be permitted...
-
11B-407.4.1 Car dimensions
area of 18 square feet (1.67 m2) minimum and also provide an inside clear depth 54 inches (1372 mm) minimum and a clear width 48 inches (1219 mm) minimum shall be permitted...
-
11B-407.4.1 Car dimensions
area of 18 square feet (1.67 m2) minimum and also provide an inside clear depth 54 inches (1372 mm) minimum and a clear width 48 inches (1219 mm) minimum shall be permitted...
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-305.3 is provided beyond the arc of the door swing.
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-305.3 is provided beyond the arc of the door swing.
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing.
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2 mentions that changes in level that do not exceed those permitted in section 303.3 are acceptable in "required clear...
-
4.2.7 Surface
The surface of the clear floor or ground space shall be firm and stable. The type of surface should be appropriate to the setting and level of development....
-
407.4.1 Car Dimensions
Inside dimensions of elevator cars and clear width of elevator doors shall comply with Table 407.4.1....