Transfer supports with circular cross sections shall have an outside diameter of 1 ¼ inches (32 mm) minimum and 2 inches (51 mm) maximum.
Search Results "Baby Changing Table"
-
M305.2.4.1 Circular Cross Section
-
M305.2.1.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be capable of supporting transfer on each side of the transfer surface.
-
M305.2.1.1 End Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.1 and M302.2 shall be located on the short side (length) opposite the transfer side.
-
M305.2.2.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer...
-
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position
5.3.1 Permitted Obstructions to Transfer Sides for Equipment Used by Patients in a Supine, Prone, Side-Lying or Seated Position. A 3-inch maximum obstruction is permitted at transfer...
-
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.3 Transfer Support Height for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. Transfer supports should be positioned 6 inches minimum and 19 inches maximum...
-
5.4.3 Transfer Support Height for M301 and M302
5.4.3 Transfer Support Height for M301 and M302 Description: Transfer support height applies to the vertical distance that the gripping area of the support is above the transfer...
-
M305.2.4.2 Non-Circular Cross Section
Transfer supports with non-circular cross sections shall have a cross-section dimension of 2 inches (51 mm) maximum and a perimeter dimension of 4 inches (100 mm) minimum and 4.8...
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
5.1.2 Transfer Surface High Height Recommendations for M301 and M302 The Committee recommends an adjustable height range with an upper height measuring at least 25...
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302 Description: Transfer side provisions are the same for M301 and M302 and require the transfer surface to be...
-
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302
5.4.8 Transfer Support Gripping Surface Hazard Recommendation for M301 and M302 Description: Gripping surface hazards are sharp or abrasive elements that prevent an individual...
-
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
5.4.8 Transfer Support Gripping Surface Hazard for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position. The gripping surfaces of the transfer support must be free of...
-
5.1.3 Transfer Surface Low Height
5.1.3 Transfer Surface Low Height. No agreement on final low height
-
5.1.2 Transfer Surface High Height
5.1.2 Transfer Surface High Height. The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches.
-
5.1.1 Transfer Surface Height Adjustability
5.1.1 Transfer Surface Height Adjustability. The transfer surface should have an adjustable height in small virtually continuous increments.
-
202.4 Alterations Affecting Primary Function Areas
constructed or altered in accordance with the April 1, 1994 Texas Accessibility Standards (TAS) they will enjoy safe harbor and are not required to be retrofitted to reflect the incremental changes...
-
804.3 Kitchen Work Surface (Exception)
The exception does not require work surfaces to be provided at kitchen counters where a table is provided within the kitchen; an electric outlet is provided within reach of the table; and...
-
Table of Contents
and Long-Term Care Facilities 224 Transient Lodging Guest Rooms 225 Storage 226 Dining Surfaces and Work Surfaces 227 Sales and Service 228 Depositories, Vending Machines, Change...
-
5 “G’s” Getting Access to Health Care for People with Physical Disabilities
By June Isaacson Kailes, Associate Director Center for Disability Issues and the Health Professions Western University of Health Sciences jik@pacbell.net 2008...
-
Accessible Medical Equipment
For participants with mobility limitations, we use exam and procedural tables and chairs that: [See Resources below and Section H] D.1....
-
Nystrom Building Products MatDesign Roll-Up Mats Premium Carpet Tread Section
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Nystrom Building Products MatDesign Roll-Up Mats Vinyl Abrasive Tread Section
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Nystrom Building Products MatDesign Roll-Up Mats with Premium carpet Tread Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Nystrom Building Products MatDesign Roll-Up Mats Vinyl Tread Section
Requires the Premium User plan or above. (Login or upgrade your account!)