1133A.3 Removable base cabinets. Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with a knee and toe space complying with...
Search Results "Single-Story Dwelling Unit (FHA)"
Commonly Searched Documents
-
1133A.3 Removable base cabinets
-
Parking at Residential Facilities
Parking at Residential Facilities
-
1132A.4.1 Thresholds
Thresholds at the primary entry and required exit doors shall be no higher than ½ inch (12.7 mm). Thresholds at secondary exterior doors, including sliding door tracks, shall be no...
-
1132A.4, Item 1
1. Exterior landings of impervious construction (e.g., concrete, brick, flagstone) serving primary entry doors and required exit doors are limited to not more than ½ inch (12.7 mm)...
-
1133A.4, Item 2
2. A minimum linear length of 30 inches (762 mm) of countertop shall be provided for a work surface.
-
1133A.2, Item 3
3. A clear floor space at least 30 inches (762 mm) by 48 inches (1219 mm) that allows either a parallel or a forward approach shall be provided at the work surface required by...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
1133A.3 Removable base cabinets
Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with knee and toe space complying with Section 1133A.7. Base cabinets (including...
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
1133A.3 Removable base cabinets
Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with knee and toe space complying with Section 1133A.7. Base cabinets (including...
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator, located...
-
C101.4 Units of Measurement (Section-by-Section Analysis)
C101.4 Units of Measurement (Section-by-Section Analysis) This proposed section, which also has a counterpart in the proposed 508 Standards (E101.4), provides that measurements are stated...
-
F229.1 General
Glazed openings in residential dwelling units required to comply with 809 shall not be required to comply with F229. 2....
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
11B-229.1 General
Exception: Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229....
-
206.6 Elevators
Elevators complying with 408 or 409 shall be permitted in multi-story residential dwelling units....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...