., entry or exit doors which open from the covered multifamily dwelling unit into a corridor, hallway or lobby, or directly to the outside)....
Search Results "Multistory Dwelling Unit (FHA)"
Commonly Searched Documents
-
1132A.1 Primary entry doors and required exit doors
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the...
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture.
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed...
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
804.3 Kitchen Work Surface (Exception)
804.3 Kitchen Work Surface (Exception) This section requires at least one work surface to be provided at kitchen counters in residential dwelling units required to provide mobility features...
-
11B-233.1 General
Public housing facilities with residential dwelling units available for public use shall comply with Section 11B-233....
-
11B-233.1 General
This section addresses long-term living (non-transient), public housing dwelling units....
-
11B-608.6 Shower spray unit and water
care facilities, transient lodging guest rooms, or residential dwelling units....
- Delta Single Function Hand Shower with Grab Bar RPW124HDF
- Delta ADA Grab Bar Hand Shower Mount U6300-WH
- Delta Adjustable Grab Bar 2-Setting Hand Shower 52001-UF
- Speakman Versatile ADA Hand Shower System VS-1001-ADA-PC
- Delta Single Function Hand Shower With Grab Bar and Elbow RPW336HDF