Wheelchair Space Overlap in Assembly Areas....
Search Results "Lavatory Clear Floor Space"
Commonly Searched Documents
-
Wheelchair Space Overlap in Assembly Areas
-
11B-504.8 Floor identification
Floor identification signs required by Chapter 10, Section 1023.9 complying with Sections 11B-703.1, 11B-703.2, 11B-703.3 and 11B-703.5 shall be located at the landing of each floor level...
-
2.4 Patient Areas
Is there space in the waiting room for wheelchair users to sit?...
-
Wheelchair Transfer
The type and extent of disability, the configuration of fixtures, and the availability of space alongside water closets often determine the technique used....
-
Vehicle Pull-Up Space: ADA Standard Section 503.2
Section 503.2 covers the current ADA Standards for vehicle pull-up space at passenger loading zones.
-
Plan 4A: 13-Foot Wide Accessible Guest Room
(section 604.5.2); • Circular turning space in room (section 603.2.1); • Required clear floor spaces at fixtures and turning space overlap (section 603.2.2); • Turning space includes...
- 606.3 Lavatory Height
-
§ 38.23(d)(2) Location and size
The securement system shall be placed as near to the accessible entrance as practicable and shall have a clear floor area of 30 inches by 48 inches....
-
11B-407.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Section 11B-302 and 11B-303....
-
In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?
Q In a doctor’s office or clinic with multiple exam rooms, must every examination room have an accessible exam table and sufficient clear floor space next to the exam table?...
-
Clear Width of Circulation Paths and Maneuvering Clearances at Wheelchair Spaces
These clearances were in addition to the requisite 30 inch by 48 inch minimum clear floor space for each wheelchair space....
- Bradley Verge Lavatory Systems
-
809.2.6 Weather Alert Systems
in emergency transportable housing units, this section requires the operable parts on weather alert systems in units with mobility features to comply with the technical requirements for clear...
-
Plan 2A: 13-Foot Wide Accessible Guest Room
); • Recessed roll-in shower location permits shorter rear grab bar at water closet (section 604.5.2); • Clear floor space adjacent to shower min. 30 inches wide by 60 inches long...
-
Transfer Space: ADA Standard Section 1009.5.2
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Seat Location: ADA Standard Section 1009.2.2
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (405 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
11B-1009.2.2 Seat location
In the raised position, the centerline of the seat shall be located over the deck and 16 inches (406 mm) minimum from the edge of the pool. The deck surface between the centerline of...
-
H8
If lavatories are provided, does at least one have at least a 29 inch high clearance under the front apron with the top of the rim no more than 34 inches above the floor?...
-
4.21.2 SIZE AND CLEARANCES
Shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
382.63 What are the requirements for accessible lavatories?
382.63 What are the requirements for accessible lavatories? As under the present rule, only aircraft with more than one aisle must have an accessible lavatory....
- Bradley Verge® Lavatory System Installation
-
§ 38.57(b)
route at least 32 inches wide so that at least two wheelchair or mobility aid users can enter the vehicle and position the wheelchairs or mobility aids in areas, each having a minimum clear...