2. Within the voting area, is adequate space available on the accessible level for check-in tables, a voting demonstration area (if provided), and at least one accessible voting...
Search Results "Latch Side Clearance"
-
2. Adequate Space
-
4.8.4 LANDINGS
Ramps shall have level landings at the bottom and top of each run. Landings shall have the following features: (1) The landing shall be at least as wide as the ramp run leading to...
-
1133A.2.1, Item 3
3. All other kitchen designs shall provide a minimum clear width of at least 48 inches (1219 mm). (See Figure 11A-10A).
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
1133A.2.1 Clear width
Kitchens shall have a minimum clear width measured between any cabinet, countertop or the face of any appliance (excluding handles and controls) that projects into the kitchen and...
-
11B-609.3 Spacing
For L-shaped or U-shaped grab bars complying with Section 11B-609.9 the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side...
-
11B-609.3 Spacing
For L-shaped or U-shaped grab bars complying with Section 11B-609.9 the space between the walls and the grab bar shall be 1½ inches (38 mm) minimum for a distance of 6 inches on either side...
-
Shape and Diameter
The 1½ inch clearance between walls and handrails is an absolute dimension; it provides knuckle clearance while preventing entrapment of the arm for people who lean on rails with their forearm...
-
4.6.4 Clear Floor or Ground Space
Knee and toe clearance complying with ABAAS section 306 shall be provided under the telescope or periscope....
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
M301.4.1 Clearance in Base
The base of the equipment shall provide a clearance 44 inches (1120 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
11B-902.4.1 Clear floor or ground space
Knee and toe clearance complying with Section 11B-306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
11B-902.4.1 Clear floor or ground space
Knee and toe clearance complying with Section 11B-306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
902.4.1 Clear Floor or Ground Space
Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24 inches (610 mm) minimum above the finish floor or ground shall be permitted....
-
1134A.8, Item 4
4. Knee and toe space. Knee and toe space shall be provided by one of the following:
-
Obstructed Reach Depth
Obstructed Reach Depth
-
1134A.8, Item 4
4. Knee and toe space. Knee and toe space shall be provided by one of the following:
-
Non-Circular Cross Section and Clearance (§505.5, §505.7)
Non-Circular Cross Section and Clearance (§505.5, §505.7)...
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
804.3.1 Clear Floor or Ground Space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with 306....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....
-
11B-804.3.1 Clear floor or ground space
The clear floor or ground space shall be centered on the kitchen work surface and shall provide knee and toe clearance complying with Section 11B-306....