Section 504 of the Rehabilitation Act of 1973 is the Federal law that protects the rights of people with disabilities to participate in Federal programs and services. ...
Search Results "Edge Protection"
Commonly Searched Documents
-
Q36. Do Federal agencies, such as the U.S. Department of Veterans Affairs, have to comply with the ADA?
-
Can van spaces required for a parking garage be located in a surface lot instead?
Open lots do not provide the same level of protection, security, and lighting as garage parking....
-
Can accessible spaces required for one parking facility be located in another one instead?
The term “user convenience” applies to factors such as protection from the weather, security, lighting, and comparative maintenance....
-
§ 38.23(d)(6) Stowage
, or when the securement area can be used by standees, the securement system shall not interfere with passenger movement, shall not present any hazardous condition, shall be reasonably protected...
-
§ 38.159(d)(6) Stowage
, or when the securement area can be used by standees, the securement system shall not interfere with passenger movement, shall not present any hazardous condition, shall be reasonably protected...
-
Q2: What is the Amendments Act?
. § 705(20)(B).5 All persons covered by Section 504 or Title II are protected from discrimination under the general nondiscrimination regulatory provisions implementing these statutes, which...
-
Water Play Components: ADA Standard Section 1008.2.3
Providing an aquatic wheelchair made of non-corrosive materials and designed for access into the water will protect the water from contamination and avoid damage to personal wheelchairs....
-
1.1.8.1 Findings and filings.
Findings prepared by fire protection districts shall be ratified by the local city, county or city and county and filed with the California Department of Housing and Community Development...
-
711.3.1.2 Through-penetration firestop system
Through penetrations shall be protected by an approved penetration firestop system installed as tested in accordance with ASTM E 814, with a minimum positive pressure differential of 0.01...
-
711.4.6 Floor fire doors
Floor fire doors used to protect openings in fire-resistance-rated floors shall be tested in the horizontal position in accordance with ASTM E 119, and shall achieve a fire-resistance rating...
-
§ 38.173(c)
(c) In stations where open platforms are not protected by platform screens, a suitable device or system shall be provided to prevent, deter or warn individuals from stepping off the platform...
-
III. "Individuals with Disabilities"
The Americans with Disabilities Act provides comprehensive civil rights protections for "individuals with disabilities". ...
-
III-3.6000 Retaliation or coercion
Individuals who exercise their rights under the ADA, or assist others in exercising their rights, are protected from retaliation....
-
1009.7.2 Separation
Openings within such fire-resistance-rated exterior walls shall be protected in accordance with Section 716....
-
Mirror Height
The guidelines specify that accessible mirrors be mounted so that the bottom edge of the reflecting surface is no higher than 40 inches (603.3)....
-
7(2)(b)(iv)
The other (non-grab bar) side of the toilet fixture is a minimum of 1'3" from the finished surface of adjoining walls, vanities or from the edge of a lavatory. (See Figure 7(a).)...
-
404.2.5 Thresholds
EXCEPTION: Existing or altered thresholds 3/4 inch (19 mm) high maximum that have a beveled edge on each side with a slope not steeper than 1:2 shall not be required to comply with 404.2.5...
-
A4.13.9 Door Hardware
To be effective, they should cover the door width, less approximately 2 in (51 mm), up to a height of 16 in (405 mm) from its bottom edge and be centered across the width of the door....
-
4.1.6(4)(c)
(i) If a safety door edge is provided in existing automatic elevators, then the automatic door reopening devices may be omitted (see 4.10.6)....
-
4.1.4 Clear Floor or Ground Space
At least 48 inches (1220 mm) of clear floor or ground space shall surround the usable sides of a picnic table, measured from the back edge of the benches....
-
11B-705.1.1.3 Color and Contrast
Detectable warning surfaces at transit boarding platform edges, bus stops, hazardous vehicular areas, reflecting pools, and track crossings shall comply with Section 11B-705.1.1.3.1....
-
11B-809.10.5.2 Reinforcement for grab bars
At the control end wall and head end wall, between 30 inches (762 mm) maximum to 38 inches (965 mm) minimum above the finish floor, extending 28 inches (711 mm) minimum from the front edge...
-
12203(b) Interference, Coercion, or Intimidation
on account of his or her having exercised or enjoyed, or on account of his or her having aided or encouraged any other individual in the exercise or enjoyment of, any right granted or protected...
-
Employer-Provided Leave and the Americans with Disabilities Act
OPPORTUNITY COMMISSION Washington, D.C. 20507 Employer-Provided Leave and the Americans with Disabilities Act1 (May 9, 2016) [1] This document also applies to Federal employees protected...