Problem Three: The bottom of a set of stairs is open and voters who are blind or have vision loss can hit their head on the underside of the stairs....
Search Results "Bottle Opener"
Commonly Searched Documents
-
Problem Three (Protruding Objects)
-
804.6.2 Operable Parts
Bottom-hinged appliance doors, when in the open position, shall not be required to comply with 309.3....
-
804.6.2 Operable Parts
Bottom-hinged appliance doors, when in the open position, shall not be required to comply with 309.3....
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-608.9 Shower floor or ground surface
Where drains are provided, grate openings shall be ¼ inch (6.4 mm) maximum and flush with the floor surface....
-
A4.13.12 Automatic Doors and Power-Assisted Doors
If slowly opening automatic doors can be reactivated before their closing cycle is completed, they will be more convenient in busy doorways....
-
A4.13.12 AUTOMATIC DOORS AND POWER-ASSISTED DOORS
If slowly opening automatic doors can be reactuated before their closing cycle is completed, they will be more convenient in busy doorways....
-
11B-607.5 Controls
Controls shall be between the bathtub rim and grab bar, and between the open side of the bathtub and the centerline of the width of the bathtub....
-
11B-608.9 Shower floor or ground surface
Where drains are provided, grate openings shall be ¼ inch (6.4 mm) maximum and flush with the floor surface....
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-810.10 Track crossings
Exception: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. FIGURE 11B-810.10 (EXCEPTION) TRACK CROSSINGS...
-
607.7 Bathtub Enclosures
Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub. [ECTCR UFAS 4.20.7]...
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
§27.71(k)(5)(iii) Captioning.
Multimedia content that contains speech or other audio information necessary for the comprehension of the content must be open or closed captioned....
-
§ 27.71(k)(5)(iii) Captioning
Multimedia content that contains speech or other audio information necessary for the comprehension of the content must be open or closed captioned....
-
Wheelchair accessible seating is required. At least one percent of the seating must be wheelchair seating locations.
Each wheelchair seating location is an open, level space that accommodates one person using a wheelchair and has a smooth, stable, and slip-resistant surface....
-
g-v
If the answers to questions g-ii thru g-iv are No, can the door be propped open? ...
-
607.7 Bathtub Enclosures
Enclosures on bathtubs shall not have tracks installed on the rim of the open face of the bathtub....
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum. Figure 810.10 (Exception) Track Crossings...
-
Gates and Barriers on Trails
If gates or barriers are constructed to control access to trails, include openings wide enough to allow hiker passage....
-
4.13.10* Door Closers
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
Automatic Door
A door equipped with a power-operated mechanism and controls that open and close the door automatically upon receipt of a momentary actuating signal....
-
4.13.10* DOOR CLOSERS
If a door has a closer, then the sweep period of the closer shall be adjusted so that from an open position of 70 degrees, the door will take at least 3 seconds to move to a point 3 in (...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...