In residential dwelling units, the height of water closets shall be permitted to be 15 inches (380 mm) minimum and 19 inches (485 mm) maximum above the finish floor measured to the top of...
Search Results "Unit Pad"
Commonly Searched Documents
-
604.4 Seats
-
604.4 Seats
In residential dwelling units, the height of water closets shall be permitted to be 15 inches (380 mm) minimum and 19 inches (485 mm) maximum above the finish floor measured to the top of...
-
11B-604.5 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in toilet or bathrooms provided that reinforcement has been installed in walls and located so as to permit...
-
Detention/Correctional and Residential Facilities (§203.7 and §203.8)
Correctional and Residential Facilities (§203.7 and §203.8) Common use spaces in detention/ correctional facilities or residential facilities that do not serve accessible cells or dwelling units...
-
Alterations Affecting Primary Function Areas—Exception to Section 202.4 of the 2010 Standards
Under the Exception to Section 202.4, residential dwelling units are exempted from this requirement....
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
-
Conditions for Exceptions
[See subsections ...]
-
1019.1 General
This section lists the conditions for the exceptions to specific provisions in 1011, 1013, 1014, 1015, 1016, 1017, and 1018. When an entity determines that any of the following...
-
[F] 907.5.2.3.4 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
-
11B-809.10.7.3 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom...
-
11B-809.10.7.4 Seat height
Water closet seats shall be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum measured to the top of the seat above the finish floor.
-
11B-809.10.8.1 Location
Lavatories without base cabinets shall be installed with the centerline 18 inches (457 mm) minimum from an adjoining wall or fixture to allow for forward approach. Lavatories with...
-
11B-809.10.8.5 Plumbing protection
Plumbing protection shall comply with Section 11B-809.9.7.
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture. The centerline of the water closet shall be...
-
11B-203.9 Employee workstations
Employee workstations shall be on an accessible route complying with Division 4. Spaces and elements within employee workstations shall only be required to comply with Sections...
-
11B-809.10.8 Lavatories, vanities, mirrors and towel bars
Bathing rooms or powder rooms required to comply with Section 11B-809.10 shall provide lavatories complying with this section. Where mirrors or towel bars are provided, no less than...
-
11B-809.10.8.4 Knee and toe clearance
Knee and toe clearance shall be provided and comply with Section 11B-306.
-
Guidelines for Requirement 6
room is subject to the requirement for reinforced walls for grab bars when the powder room is the only toilet facility located on the accessible level of a covered multistory dwelling unit...
-
233.3.4.1 Alterations to Vacated Buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...
-
[F] 907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support...
- Figure 608.5.2 Standard Roll-In Type Shower Compartment Control Location – Drawing from the U.S. Access Board
-
233.3.4.1 Alterations to Vacated Buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...
-
11B-606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted where rough-in plumbing...
-
11B-606.3 Height
In residential dwelling unit kitchens, sinks that are adjustable to variable heights, 29 inches (737 mm) minimum and 36 inches (914 mm) maximum, shall be permitted where rough-in plumbing...