Doors required to be accessible by 4.1 shall comply with the requirements of 4.13....
Search Results "Shower Door"
Commonly Searched Documents
- 
    
  
  4.13.1 GENERAL
  
 - 
    
  
  Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]
  
Clear Width and Vertical Clearance of Doors and Gates [§404.2.3]...
 - 
    
  
  Re: 608.2.3 Alternate Roll-In Type Shower Compartments
  
What does a good alternate roll-in shower look like?...
 - 
    
  
  1132A.6 Closer-effort to operate doors
  
1132A.6 Closer-effort to operate doors....
 - 
    
  
  4.1.3(7)(a)
  
(a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
 - 
    
  
  1132A.6 Closer-effort to operate doors
  
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
 - 
    
  
  1132A.6 Closer-effort to operate doors
  
Maximum effort to operate doors shall not exceed 8½ pounds (38 N) for exterior doors and 5 pounds (22 N) for interior doors, such pull or push effort being applied at right angles to hinged...
 - ADAEZ Pro Plus Automatic Door Opener Installing Door Arm Pivot Video
 - 
    
  
  F206.5.1 Entrances
  
Each entrance to a building or facility required to comply with F206.4 shall have at least one door, doorway, or gate complying with 404....
 - 
    
  
  206.5.1 Entrances
  
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
 - 
    
  
  F206.5.2 Rooms and Spaces
  
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
 - 
    
  
  206.5.2 Rooms and Spaces
  
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
 - 
    
  
  206.5.1 Entrances
  
Each entrance to a building or facility required to comply with 206.4 shall have at least one door, doorway, or gate complying with 404....
 - 
    
  
  1134A.6, Item 1.1
  
1.1 The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or...
 - 
    
  
  1134A.6, Item 1.1
  
The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or...
 - 
    
  
  § 38.157(a)
  
(a) Any stepwell or doorway immediately adjacent to the driver shall have, when the door is open, at least 2 foot-candles of illumination measured on the step tread....
 - 
    
  
  206.5.2 Rooms and Spaces
  
Within a building or facility, at least one door, doorway, or gate serving each room or space complying with these requirements shall comply with 404....
 - 
    
  
  Can handrails overlap door maneuvering clearances?
  
No, door maneuvering clearances must be free of any overlapping objects, even those providing knee and toe clearance, which can interfere with maneuvering at doors and doorways....
 - 
    
  
  H. Door Maneuvering Clearance
  
On the pull side of each door (i.e.: entry door, connecting room door, bathroom doors and other passage doors) in every accessible guestroom/suite, are there at least 18" of clear floor...
 - 
    
  
  407.3.3.3 Duration
  
Door reopening devices shall remain effective for 20 seconds minimum....
 - 
    
  
  407.3.3.3 Duration
  
Door reopening devices shall remain effective for 20 seconds minimum....
 - 
    
  
  11B-407.3.3.3 Duration
  
Door reopening devices shall remain effective for 20 seconds minimum....
 - 
    
  
  11B-407.3.3.3 Duration
  
Door reopening devices shall remain effective for 20 seconds minimum....
 - 
    
  
  11B-407.3.3.3 Duration
  
Door reopening devices shall remain effective for 20 seconds minimum....