All required ramps and curb ramps must be permanent and installed at the time of construction or alteration with few exceptions....
Search Results "Parallel Curb Ramp"
Commonly Searched Documents
- 
    
  
  Can ramps be portable or provided after construction as an adaptation?
  
- 
    
  
  Program Accessibility
  ramps where roads intersect pedestrian access routes (sidewalks or other pedestrian walkways). ... 
- 
    
  
  4.2 Physical Accessibility Barriers and Solutions
  Use cones and/or tape and temporary signs to mark additional parking spaces Restripe parking area to include ADAAG required widths for accessible parking spaces No curb... 
- 
    
  
  11B-608.7 Thresholds
  Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303. [2010 ADAS] 608.7 Thresholds. Thresholds in roll-in type... 
- 
    
  
  11B-608.7 Thresholds
  11B-608.7 Thresholds. Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303. [2010 ADAS] 608.7 Thresholds.... 
- 
    
  
  11B-608.7 Thresholds
  Thresholds in roll-in type shower compartments shall be ½ inch (12.7 mm) high maximum in accordance with Section 11B-303. In transfer type shower compartments, thresholds ½ inch... 
- 
    
  
  11B-1008.2.5.1 Ground level
  Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.... 
- 
    
  
  1008.2.5.1 Ground Level
  Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.... 
- 
    
  
  1008.2.5.1 Ground Level
  Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.... 
- 
    
  
  11B-1008.2.5.1 Ground level
  Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.... 
- 
    
  
  11B-1008.2.5.1 Ground level
  Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.... 
- 
    
  
  405.2 Slope (Exception 2), 405.6 Rise (Exception)
  The running slope of ramp runs must not be steeper than 1:12 and any ramp rise must be 30 inches maximum.... 
- 
    
  
  1008.2.5.1 Ground Level
  Ramp runs connecting ground level play components shall have a running slope not steeper than 1:16.... 
- 
    
  
  11B-805.2.2 Beds
  The clear floor space shall be positioned for parallel approach to the side of the bed.... 
- 
    
  
  11B-805.2.2 Beds
  The clear floor space shall be positioned for parallel approach to the side of the bed.... 
- 
    
  
  11B-805.2.2 Beds
  The clear floor space shall be positioned for parallel approach to the side of the bed.... 
- 
    
  
  6. Ramps
  Ramps 4.8 Accessible routes with slopes greater than 1:20.... 
- 
    
  
  11B-502.4 Floor or ground surfaces
  Built-up curb ramps are not permitted to project into access aisles and parking spaces because they would create slopes greater than 1:48.... 
- 
    
  
  11B-502.4 Floor or ground surfaces
  Built-up curb ramps are not permitted to project into access aisles and parking spaces because they would create slopes greater than 1:48. ... 
- 
    
  
  Re: 405 Ramps
  Gentlemen/Ladies: While the code requires a 60"x 60" clear landing, does it have to be square? Please see attached and advise, thank you. 
- 
    
  
  Fittings: ADA Standard Section 505.9
  Section 505.9 covers the current ADA Standards for handrail fittings. 
- 
    
  
  11B-505.9 Fittings
  Handrails shall not rotate within their fittings. 
- 
    
  
  11B-405.7.1 Slope
  Landings shall comply with Section 11B-302. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved. 
- 
    
  
  § 38.95(c)(6)(i) Requirement
  When in use for boarding or alighting, the ramp or bridge plate shall be attached to the vehicle, or otherwise prevented from moving such that it is not subject to displacement when loading... 