Commonly Searched Documents
- ADA25: #17 of 25 -- Recreation
-
Fair Housing Act Design Manual
The Manual provides direct information about the accessibility requirements of the Act which must be incorporated into the design and construction of multifamily housing covered by the Act...
-
2.7 Existing ADA and Rehabilitation Act Requirements for Accessible Medical Care
2.7 Existing ADA and Rehabilitation Act Requirements for Accessible Medical Care The Americans with Disabilities Act (ADA) and Section 504 of the Rehabilitation Act are civil rights laws...
-
Department of Justice
Department of Justice offers technical assistance on the ADA Standards for Accessible Design and other ADA provisions applying to businesses, non-profit service agencies, and state...
-
General Requirements of Part 382
In a nutshell, the main requirements of Part 382 regarding service animals are: Carriers shall permit dogs and other service animals used by persons with disabilities to...
-
10. How do the IDEA FAPE and the Title II effective communication requirements differ with regard to the obligation to provide communication for students with disabilities attending public elementary and secondary schools?
Answer. The Title II regulations explicitly require that a district take appropriate steps to ensure that communications with persons with disabilities are “as effective as”...
-
2. Standing Supports
received two comments, one of which addressed standing supports on mammography equipment (discussed above in Section IV.D.1 (Significant Changes – Standing Supports)) and one commenter (medical...
-
3.2 Getting on the Table
The Patient’s Perspective on Access to Medical Equipment. In J. Winters and M. Story (Ed.), Medical Instrumentation: Accessibility and Usability Considerations (pp. 3-14)....
-
5.9.2.1 Standing Supports on Single Ramped Entry Raised Platforms with Wheelchair Spaces Recommendations
Standing supports can also act as a guide to help the user to better position her or himself onto the platform....
-
M302 Diagnostic Equipment Used by Patients in Seated Position
[See subsections ...]
-
M303.2.4.1 Breast Platforms
Wheelchair spaces beneath breast platforms shall comply with M303.2.4.1.
-
M303.2.4.1.1 Depth
Wheelchair spaces shall include knee and toe clearance 25 inches (635 mm) deep minimum and 28 inches (710 mm) deep maximum.
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair...
-
11B-223.2 Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities
Hospitals, rehabilitation facilities, psychiatric facilities and detoxification facilities shall comply with Section 11B-223.2. All public use and common use areas shall be...
-
a. Knee and Toe Clearance
The proposed rule recommended a knee and toe clearance depth for breast platforms of 25 inches. There were no comments received on this requirement. The MDE Advisory Committee...
-
M302 Diagnostic Equipment used by Patients in a Seated Position (Section-by-Section Analysis)
M302 in the final rule establishes the technical criteria for diagnostic equipment used by patients in a seated position such as examination chairs.
-
5.8.2.4 Unobstructed Floor Space Recommendation
5.8.2.4 Unobstructed Floor Space Recommendation The Committee recommends the unobstructed floor space in front of the base support be a minimum of 17 inches deep. Rationale for...
-
5.8.2 Knee and Toe Clearance Under Breast Platform
5.8.2 Knee and Toe Clearance Under Breast Platform. The overall knee and toe space should be increased to a minimum of 28 inches deep, from the initially proposed 25 inch absolute...
-
2. Equipment Clearances for Breast Platforms
The MDE NPRM proposed knee and toe clearance requirements for diagnostic equipment used by patients seated in wheelchairs that paralleled the knee and toe clearance requirements from...
-
§301(7)(F)
A laundromat, dry-cleaner, bank, barber shop, beauty shop, travel service, shoe repair service, funeral parlor, gas station, office of an accountant or lawyer, pharmacy, insurance...
-
5.8.2.5 Toe Height
5.8.2.5 Toe Height. The toe height should be 18 inches minimum, measured above the ground when the top of the breast platform is 34 inches above the ground.
-
5.8.2.7 Base Support Allowance
5.8.2.7 Base Support Allowance. Base support is permitted to obstruct the clear floor space if it fits within the allowed base support volume. Base supports can be a maximum of 1½...
-
5.8.2.2 Knee Clearance Depth at 27” Above the Ground
5.8.2.2 Knee Clearance Depth at 27” Above the Ground. The knee clearance should be increased at 27 inches above the ground to 18 inches minimum.