Diagnostic equipment used by patients in a standing position shall comply with M304....
Search Results "Patient Toilet Room"
-
M304.1 General
-
Portable Units [4.1.2(6)]
Portable Units [4.1.2(6)] Where portable single-user toilet or bathing units are provided at exterior sites, at least 5%, but no less than one, must be accessible at each location....
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
M301.2.3 Transfer Surface Transfer Sides
The option to transfer will be required only on one long side of the patient scanning/imaging table and not at the “foot” or “head” end of such surfaces....
-
11B-241.1 General
Where provided, saunas and steam rooms shall comply with Section 11B-612....
-
11B-241.1 General
Where provided, saunas and steam rooms shall comply with Section 11B-612....
- Georgia Pacific Compact® Tissue Dispensers - Vertical and Quad Loading Instructions
-
5.7.1.2 Lift Compatibility Clearance in Base for Imaging Equipment (M301)
Some imaging systems already use overhead lifts to assist patients. Overhead lifts are not feasible in the MR exam room due to the magnetic fields....
-
5.9 Standing Support for Equipment Used by Patients in a Standing Position
5.9 Standing Support for Equipment Used by Patients in a Standing Position....
- Hill-Rom Liko® M220 / M230 Mobile Lift, Senior Video
- Hill-Rom Liko® M220 / M230 Mobile Lift, Pediatric Video
-
B. Accessible Routes To All Service/Activity Areas
This includes people who use mobility devices, such as wheelchairs and scooters, being able to get to locations where supplies are distributed, to eating areas, to sleeping areas, to toilet...
-
5.3 Pit Toilets
[See subsections ...]
-
612 Saunas and Steam Rooms
612 Saunas and Steam Rooms...
-
F213.1 General
A pit toilet is a primitive outhouse consisting of a toilet riser over a hole dug into the ground or receptacle to receive and naturally decompose human waste....
- Gamco Recessed Multi-Roll Toilet Tissue Dispenser - TTD-6
-
§ 38.107(b)
(b) Restrooms required to be accessible shall be in close proximity to at least one seating location for persons using mobility aids and shall be connected to such a space by an...
-
4. Getting What You Need During Your Visit
Sometimes you may face barriers that cannot be immediately addressed, for example, when there is no available accessible scale. So what can you do to be as prepared as possible...
-
M301.3 Transfer Supports
Height: Located no less than 6 inches (150 mm) and no more than 19 inches (482 mm) above the patient support surface Horizontal Distance from Transfer Surface: No more than 3 inches (...
-
M301.2.2 Transfer Surface Size
The minimum size of the transfer surface is 28 inches wide minimum and 21 inches deep minimum and is located such that the long dimension of 28 inches is be located parallel to the patient...
-
M301.1 General (Section-by-Section Analysis)
The MDE NPRM proposed that all diagnostic equipment used by patients in a supine, prone, or side-lying position must comply with the technical requirements of proposed section M301....
-
M301.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M301.4.1 or M301.4.2....
-
M301.2.2, M302.2.2 Transfer Size
M301.2.2, M302.2.2 Transfer Size Proposed requirement: 30" wide minimum and 15" deep minimum • Sub-Committee Recommendation: 28" wide minimum and 17" deep minimum. This...
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
Exception: General exam rooms in non-emergency settings may provide clear space on only one side of beds, gurneys and exam tables....