11B-707.6.1 Input controls. At least one tactilely discernible input control shall be provided for each function....
Search Results "Operation (Control)"
-
11B-707.6.1 Input controls
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
403.1 General
Where provided, biometrics shall not be the only means for user identification or control....
- DORMA ED900 Low-Energy Swing Door Operator
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section 11B-703.3....
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2, and Braille complying with Section 11B-703.3....
-
11B-407.4.7.1.1 Type
Control buttons shall be identified by raised characters or symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
- Somfy Window Covering Controls and Intergration with myLinkโข App
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
- Figure 703.7.2.3 Volume Control Telephone โ Drawing from the U.S. Access Board
- BEA Inc. Product Line: ACPB Access Control Push Button (Push to Exit)
- NABCO GT300 & GT8300 Overhead Concealed Low-Energy Swing Door Operator
-
412.1 General
Where ICT displays or processes video with synchronized audio, ICT shall provide a mode of operation that plays associated audio description....
-
ยง382.7(b)
(b) If you are a foreign carrier, this part applies to you only with respect to flights you operate that begin or end at a U.S. airport and to aircraft used for these flights....
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2....
-
407.4.7.1.1 Type
Control buttons shall be identified by tactile characters complying with 703.2....
-
11B-411.4.7 Designations and indicators of car control buttons
Designations and indicators of car control buttons shall comply with Section 11B-411.4.7....
-
11B-411.4.7 Designations and indicators of car control buttons
Designations and indicators of car control buttons shall comply with Section 11B-411.4.7....
-
11B-411.4.7 Designations and indicators of car control buttons
Designations and indicators of car control buttons shall comply with Section 11B-411.4.7....
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.