A sink and work surface in a single integral unit 60 inches (1524 mm) minimum in length, is permitted....
Search Results "Multi-Story Residential Dwelling Unit"
-
11B-809.9.4 Work surfaces
-
Section 35.151(e) Social service center establishments (Section-by-Section Analysis)
dwelling units to comply with the provisions of the 2004 ADAAG that apply to residential facilities, including, but not limited to, the provisions in sections 233 and 809....
-
11B-229.1 General
Glazed openings in residential dwelling units required to comply with Section 11B-809 shall not be required to comply with Section 11B-229. 2. ...
-
11B-233.3.1.2.6.3 Test number two, site analysis test
Determine the requirement of providing an accessible route to planned multifamily dwellings based on the topography of the existing natural terrain....
-
11B-604.3.2 Overlap
The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible...
-
907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
-
4.3.2(3)
(3) At least one accessible route shall connect accessible building or facility entrances with all accessible spaces and elements and with all accessible dwelling units within the building...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-809.10.5.1 Clear floor space
A clear floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be located with the long edge of the clear floor space parallel to the side of the bathtub or...
-
[F] 907.5.2.3.4 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, all dwelling units and sleeping units shall be provided with the capability to support visible alarm notification...
-
11B-233.3.4.1 Alterations to vacated buildings
In addition, at least 2 percent of the residential dwelling units shall comply with Section 11B-809.5 _|Residential Dwelling Units with Communication Features|_....
-
11B-233.3.4.1 Alterations to vacated buildings
In addition, at least 2 percent of the residential dwelling units shall comply with Section 11B-809.5 _|Residential Dwelling Units with Communication Features|_....
-
4(3)
(3) In multistory dwelling units in buildings with elevators, the story of the unit that is served by the building elevator (a) is the primary entry to the unit; (b) complies with Requirements...
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator, located...
-
11B-233.3.1.2.6 Public housing facility site impracticality
The site impracticality tests in this section may be used to determine the number of required residential dwelling units with adaptable features in buildings without an elevator, located...
-
11B-233.3.4.1 Alterations to vacated buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...
-
11B-809.10.5.3 Controls
Exception: Shower spray units are not required in bathtubs....
-
4.1 Q. If an owner adds four or more dwelling units to an existing building, are those units covered by the Fair Housing Act?
Yes, provided that the units constitute a new addition to the building and not substantial rehabilitation of existing units....
-
3.2 Q. If a condominium is pre-sold as a shell and the interior is designed and constructed by the buyer, are the Guidelines applicable?
The Fair Housing Act applies to design and construction of covered multifamily dwellings, regardless of whether the person doing the design and construction is an architect, builder, or...
-
Common Use Areas in Residential Facilities—Section 203.8 of the 2010 Standards
Section 203.8 of the 2010 Standards provides that, in residential facilities, common use areas that do not serve residential dwelling units required to provide mobility features are not...
-
708.4.1 Common Use or Public Use System Interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....
-
11B-708.4.1 Common use or public use system interface
The common use or public use system interface shall include the capability of supporting voice and TTY communication with the residential dwelling unit interface....