Grab bars shall not be required to be installed in a shower located in a bathing facility for a single occupant accessed only through a private office, and not for common use or public use...
Search Results "Fixed Shower Head"
Commonly Searched Documents
-
11B-608.3 Grab bars
-
11B-608.3 Grab bars
Grab bars shall not be required to be installed in a shower located in a bathing facility for a single occupant accessed only through a private office, and not for common use or public use...
-
ยง 37.33 Airport transportation systems
[See subsections ...]
-
Clear Floor or Ground Space: ADA Standard Section 902.4.1
A clear floor space complying with 305 positioned for forward approach shall be provided. Knee and toe clearance complying with 306 shall be provided, except that knee clearance 24...
-
4.34.5.5(5) Shower unit
(5) Shower unit. A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head at various heights or as a hand-held shower shall be provided....
-
4.34.5.4(5) Shower unit
(5) Shower unit. A shower spray unit with a hose at least 60 in (1525 mm) long that can be used as a fixed shower head or as a hand-held shower shall be provided....
-
11B-224.1.2 Guest room doors and doorways
Exception: Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
11B-224.1.2 Guest room doors and doorways
Exception: ย Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
11B-224.1.2 Guest room doors and doorways
Exception: ย Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
Swanstone Barrier-Free Shower Floor FBF-3464
Requires the Premium User plan or above. (Login or upgrade your account!)
- Figure 608.2.3 Alternate Roll-In Type Shower Compartment Size and Clearance โ Drawing from the U.S. Access Board
-
Requirement 6. Reinforced walls for grab bars.
stall and shower seat, where such facilities are provided....
-
11B-809.10.6.5 Thresholds
Where provided thresholds shall be 2 inches (51 mm) maximum in height and have a beveled or sloped angle not exceeding 1 unit vertical in 2 units horizontal (26.6 degrees from the...
-
11B-206.5.3 Transient lodging facilities
Exception: ย Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
-
11B-206.5.3 Transient lodging facilities
Exception: ย Shower and sauna doors in guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall not be required to comply with Section 11B-404.2.3...
- Inclusion Solutions Freestanding Totem Pocket Display
-
F201.3 Temporary and Permanent Structures
Temporary buildings or facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed...
-
201.3 Temporary and Permanent Structures
Temporary buildings or facilities covered by these requirements include, but are not limited to, reviewing stands, temporary classrooms, bleacher areas, stages, platforms and daises, fixed...
-
11B-902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground.
-
902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground.
-
902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground.
-
902.3 Height
902.3 Height. The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground.
-
11B-902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground.
-
11B-902.3 Height
The tops of dining surfaces and work surfaces shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground.