Nonworking parts, such as platform, frame, and attachment hardware which would not be expected to wear, shall have a safety factor of at least three, based on the ultimate strength of the...
Search Results "Platform Accessibility Services"
-
§ 38.23(b)(1) Design load
-
§ 38.23(b)(3) Emergency operation
be capable of being operated in a manner that could be hazardous to the lift occupant or to the operator when operated according to manufacturer's instructions, and shall not permit the platform...
-
§ 38.159(b)(3) Emergency operation
be capable of being operated in a manner that could be hazardous to the lift occupant or to the operator when operated according to manufacturer's instructions, and shall not permit the platform...
-
§ 38.95(b)(1) Design load
Nonworking parts, such as platform, frame, and attachment hardware which would not be expected to wear, shall have a safety factor of at least three, based on the ultimate strength of the...
-
§ 38.125(b)(1) Design load
Nonworking parts, such as platform, frame, and attachment hardware which would not be expected to wear, shall have a safety factor of at least three, based on the ultimate strength of the...
-
§ 38.83(b)(3) Emergency operation
be capable of being operated in a manner that could be hazardous to the lift occupant or to the operator when operated according to manufacturer's instructions, and shall not permit the platform...
-
§ 38.83(b)(1) Design Load
Nonworking parts, such as platform, frame, and attachment hardware which would not be expected to wear, shall have a safety factor of at least three, based on the ultimate strength of the...
-
TABLE OF CONTENTS
11B-222 Dressing, fitting, and locker rooms 11B-223 Medical care and long-term care facilities 11B-224 Transient lodging guest rooms, housing at a place of education and social service...
-
18.1 Q. Is it necessary to provide usable doors when the door leads to an area of the dwelling that is not accessible, such as the door leading down to an unfinished basement...?
This will ensure that, if a wheelchair user occupying the dwelling unit chooses to modify the unit to provide accessibility to these areas, such as installing a ramp from the dwelling unit...
-
Study Limitations
There was not a backrest available behind the second platform for the two-step transfers....
-
11B-233.1 General
§35.102(a) “this part applies to all services, programs or activities provided or made available by public entities....
-
1136A.2 Switch and control heights
than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor or working platform...
-
1136A.2 Switch and control heights
than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor or working platform...
-
1136A.2 Switch and control heights
than 48 inches (1219 mm) measured from the top of the outlet box nor less than 15 inches (381 mm) measured from the bottom of the outlet box to the level of the finished floor or working platform...
-
Restricted Entrance
An entrance that is made available for common use on a controlled basis but not public use and that is not a service entrance....
-
RESTRICTED ENTRANCE
An entrance that is made available for common use on a controlled basis, but not public use, and that is not a service entrance....
-
RESTRICTED ENTRANCE
An entrance that is made available for common use on a controlled basis, but not public use, and that is not a service entrance....
-
Place of Public Accommodation
On- or off-site management and reservations service; 2. Rooms available on a walk-up or call-in basis; 3....
-
1.2 MDE Advisory Committee Membership
Access Board published the list of organizations selected for representation on the Medical Diagnostic Equipment Accessibility Standards Advisory Committee (the MDE Advisory Committee)....
-
504.1 General
Where an application is an authoring tool, the application shall conform to 504 to the extent that information required for accessibility is supported by the destination format....
-
C. Architectural Barrier Removal (Non-seating)
Olympia shall address certain of Joe Louis Arena’s architectural barriers to access, including parking, signage, entrances, locker rooms, first aid rooms, rest rooms, restaurants,...
-
Do requirements for “public entrances” apply only to those entrances used by the public?
No, scoping provisions for accessible public entrances are not limited to those used by the public....
-
H. Transitions Back to the Community
In some instances, shelter operators have required individuals with disabilities to move to hospitals, nursing homes, or other institutions when these individuals could not locate accessible...
-
G.5.ii. - How is the "back office" exception applied?
First, the agency must intend to locate the product in a physical space frequented only by service personnel....