Flush Controls [4.18.4] Flush controls must be mounted no more than 44 inches above the finished floor and must: be automatic or operable by one hand operate without...
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
Flush Controls [4.18.4]
-
11B-1002.4.1 Floor or ground surface
The floor or ground surface of wheelchair spaces shall be stable and firm....
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
- Mansfield Urinal Brevity ADA Commercial Package CP-422
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor....
- Kohler Branham™ Urinal K-4920-R-0
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
11B-1009.2.3 Clear deck space
On the side of the seat opposite the water, a clear deck space shall be provided parallel with the seat....
-
Floor or Ground Surface: ADA Standard Section 404.2.4.4
Section 404.2.4.4 covers the current ADA Standards for floor or ground surfaces at door maneuvering clearances.
-
Section H: Lifts
(§410.1) H3 Is there 30" by 48" of clear floor space within the lift?...
-
ETA Questions: Interpretation of the "Changes in Level Are Not Permitted" Requirements
There are a number of places in the 2010 ADA Standards where the phrase "Changes in level are not permitted" occurs. However, the interpretation of this phrase is not clearly...
-
Turning Space: ADA Standard Section 304
Section 304 covers the current ADA Standards for turning space.
- TOTO® Commercial Washout High Efficiency Urinal, 0.5 GPF - ADA
- Mansfield Urinal Suburban Commercial 475
-
1133A.7, Item 3
A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm)....
-
1133A.7, Item 3
A clear floor space shall not extend into the knee and toe space more than 19 inches (483 mm)....
-
7(2)(b)(vi)
(vi) Bathtubs and tub/showers located in the bathroom provide a clear access aisle adjacent to the lavatory that is at least 2'6" wide and extends for a length of 4'0" (measured from the...
-
31.1 Q. Can a water closet (toilet) be located in an alcove with a wing wall?
Yes, as long as the necessary clear floor space shown in Figure 7(a) is provided....
-
Turning Space [§304]
Turning Space [§304] Turning space is required in these accessible rooms and spaces: toilet and bathing facilities dressing, fitting, and locker rooms transient...
- Murdock Manufacturing Washout Stall Urinal, Front Mount
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width....
-
1134A.7, Item 1
Floor space and location. The minimum floor space provided at a water closet shall be 48 inches (1219 mm) in clear width. ...