The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
Search Results "Transfers of Privately Held Equity Interest"
-
11B-1008.3.1.2 Height
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-608.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
11B-608.6 Shower spray unit and water
A shower spray unit with a hose 59 inches (1499 mm) long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided....
-
5.1.4 Transfer Surface Height Measurement for M301 and M302
5.1.4 Transfer Surface Height Measurement for M301 and M302 The Committee recommends capturing the transfer surface height at the highest point of the seat in an uncompressed state, inclusive...
-
5.1.2 Transfer Surface High Height Recommendations for M301 and M302
Therefore, transfer surfaces that are adjustable to a 25 inches maximum during patient transfer accommodate most patients who use mobility devices....
-
1f
Is there a horizontal grab bar on the wall alongside the shower seat (but not behind the shower seat) for stabilization and to aid in transfer from a wheelchair to the folding shower seat...
-
(4) Adjustability: Method of Measurement
used in the seated position, be taken from the floor to the top of the transfer surface (proposed M301.2.1 and M302.2.1, respectively)....
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302 Description: The transfer surface size standard has two components: width and depth....
-
5.1.1 Transfer Surface Height Adjustability Recommendation for M301 and M302
For some, independent transfers are only possible when there is minimal or no change in vertical height between the seat of the mobility device and the transfer surface....
-
SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND ATLANTA'S JOHN MARSHALL LAW SCHOOL UNDER THE AMERICANS WITH DISABILITIES ACT
[See subsections ...]
-
M301.2.3.1 End Transfer Surface
End transfer surfaces shall be 28 inches (710 mm) wide minimum and 17 inches (430 mm) long minimum. ...
-
M301.2.3.2 Side Transfer Surface
Side transfer surfaces shall be 28 inches (710 mm) wide minimum and 28 inches (710 mm) long minimum....
-
2004 ADA and ABA Accessibility Guidelines
The following technical criteria in the proposed standards are based on the 2004 ADA and ABA Accessibility Guidelines: • Height of transfer surfaces on diagnostic equipment used by patients...
-
A4.16.4 Grab Bars
A6(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet....
-
A4.16.4 GRAB BARS
A5(a) and (b) show the diagonal and side approaches most commonly used to transfer from a wheelchair to a water closet....
-
A. Designating an ADA Coordinator
The name, office address, and telephone number of the ADA Coordinator must be provided to interested persons. Common Question: Which employees count?...
-
Hologic, Inc.
It is only after these images are taken and a region of interest (e.g., calcifications or suspicious architectural distortion) has been detected that a patient will be required to go for...
-
M301.3.1 Transfer Supports (Section-by-Section Analysis)
The MDE NPRM proposed to require transfer supports to be provided for use with transfer sides on diagnostic equipment used by patients in the supine, prone, or side-lying position, and that...
-
11B-608.5.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19 inches (483...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the...
-
608.5.3 Alternate Roll-In Type Shower Compartments
608.5.3 Alternate Roll-In Type Shower Compartments. In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar,...
-
608.5.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, the controls, faucets, and shower spray unit shall be located above the grab bar, but no higher than 48 inches (1220 mm) above the...