Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope....
Search Results "Side-Opening Door"
-
11B-809.8.1 Door Thresholds
-
B. Measuring Clear Passage at Doors
Verifying the clear passage width at standard hinged doors requires an understanding of exactly where to measure....
-
404 Doors, Doorways, and Gates
[See subsections ...]
-
404 Doors, Doorways, and Gates
[See subsections ...]
-
404 Doors, Doorways, and Gates
[See subsections ...]
-
404 Doors, Doorways, and Gates
[See subsections ...]
-
404 Doors, Doorways, and Gates
[See subsections ...]
-
4.35.3 Doors
All doors to accessible dressing rooms shall be in compliance with section 4.13....
-
4.10.7* Door and Signal Timing for Hall Calls
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
4.10.7* DOOR AND SIGNAL TIMING FOR HALL CALLS
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D or T = D...
-
11B-404.2.7 Door and gate hardware
Where sliding doors are in the fully open position, operating hardware shall be exposed and usable from both sides. [Safe Harbor only applies to existing primary entrances.]...
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-813.2.10 Door swing
A door, in any position, shall be permitted to encroach into the turning space by 12 inches (305 mm) maximum....
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
11B-304.4 Door swing
Doors shall be permitted to swing into turning spaces....
-
Other Requirements in the ADA Standards
Automated Doors Maneuvering clearance is required on the egress side of automated doors unless they are equipped with standby power or they stay open in power-off mode (§404.3.2)...
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
Maneuvering Clearances [§404.2.4]
Maneuvering Clearances [§404.2.4] Required maneuvering clearances provide space for opening and proceeding through doors, doorways, and gates using wheelchairs and other mobility aids...
-
Are side flares required at curb ramps?
The ADA Standards do not require that curb ramps have side flares, but limit the slope (1:10 max.) where they are provided....
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....