doors and doorways in inaccessible transient lodging guest rooms in section 206.5.3 (located at 224.1.2 in the proposed rule) addition of a new exception from this requirement for shower...
Search Results "Shower Drain"
Commonly Searched Documents
-
Doors, Doorways, and Gates
-
A4.34.5 BATHROOMS
Although not required by these specifications, it is important to install grab bars at toilets, bathtubs, and showers if it is known that a dwelling unit will be occupied by elderly or severely...
-
11B-603.6 Guest room toilet and bathing rooms
fixtures in a location that allows a person using a wheelchair measuring 30 inches by 48 inches (762 mm by 1219 mm) to touch the wheelchair to any lavatory, urinal, water closet, tub, sauna, shower...
-
Clear Deck Space
This virtually flat area will make the transfer easier and safer, while still allowing water to drain away from the deck....
- Wetland Trail Design and Construction
- Haws ANSI Z358.1 - 2009 Compliance
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-213.2.3 Unisex (Patient) bathing rooms in medical care and long-term care facilities
Common-use unisex bathing rooms for exclusive patient use not located within patient bedrooms shall contain one shower or one bathtub, one lavatory, and one water closet....
-
11B-224.2.2 More than fifty guest room facilities
MINIMUM NUMBER OF REQUIRED ROOMS WITH ROLL-IN SHOWERS TOTAL NUMBER OF REQUIRED ROOMS 1 to 25 0 [2010...
-
Types of Alternative Designs
Shower: Roll-in showers were used, but sidewalls were minimized to permit access by a caregiver from outside the fixture....
-
Alternative Designs
First, it must be drained to open the door to exit the fixture. As a result, an older individual who can only get out through the door must sit in the tub until it is drained....
-
Doorways
Clarification was requested on which types of doors this is intended to cover and whether it applies to shower doors. Response....
-
Q3.) What are the types of “manufacturing processes” that were anticipated where the advisory says “tolerances recognized by this provision include… “those that may be a necessary consequence of a particular manufacturing process”?
One example of a manufacturing process that would fall into this category is the manufacturing of fiberglass shower stalls. ...
-
Landings [4.8.4]
It is recommended that landings of exterior ramps be drained so that water does not accumulate on the surface....
-
Outdoor Constructed Features
Picnic tables, fire rings, grills, fireplaces, wood stoves, trash and recycling receptacles, water hydrants, utility and sewage hookups, outdoor rinsing showers, benches, and viewing scopes...
-
Outdoor Constructed Features
Picnic tables, fire rings, grills, fireplaces, wood stoves, trash and recycling receptacles, water hydrants, utility and sewage hookups, outdoor rinsing showers, benches, and viewing scopes...
-
Accessible Hotel Rooms (Preamble, Section-by-Section Analysis)
In addition, 1% of the rooms must have roll-in showers....
-
607.7 Bathtub Enclosures
Enclosures for bathtubs shall not obstruct controls, faucets, shower and spray units or obstruct transfer from wheelchairs onto bathtub seats or into bathtubs....
-
11B-607.7 Bathtub enclosures
Enclosures for bathtubs shall not obstruct controls, faucets, shower and spray units or obstruct transfer from wheelchairs onto bathtub seats or into bathtubs....
-
4.1.5(3) TOILET AND BATHING FACILITIES
provided in the existing building, then at least one toilet and bathing facility in the existing building shall comply with 4.22, Toilet Rooms, or 4.23, Bathrooms, Bathing Facilities, and Shower...
-
Accessible Hotel Rooms (Section-By-Section Analysis and Response to Comments)
In addition, 1% of the rooms must have roll-in showers....
-
11B-607.7 Bathtub enclosures
Enclosures for bathtubs shall not obstruct controls, faucets, shower and spray units or obstruct transfer from wheelchairs onto bathtub seats or into bathtubs....
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
The 2010 Standards provide a gap of 3 inches between the edge of a shower seat and the shower compartment entry, and the gap does not appear to interfere with transferring onto and off the...