Search Results "Shower Compartment"
- Inpro Corporation ENDURANT® Partition Post
-
Hadrian Inc. Solid Plastic Headrail Braced - Integral Hinge - Toilet Partitions
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Hadrian Inc. Headrail Braced Toilet Partition
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Hadrian Inc. Ceiling Hung Toilet Partition
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation ENDURANT® Partition Door
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Hadrian Inc. Powder Coated Toilet Partition Headrail Braced - Elite Plus
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Hadrian Inc. Toilet Partition Color Options
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation ENDURANT® Partitions Lateral Bracing
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Hadrian Inc. Floor to Ceiling Toilet Partition
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Inpro Corporation ENDURANT® Partition Wall Panel
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
-
1134A.6, Item 3
A clear maneuvering space at least 30 inches in width by 48 inches in length (762 mm by 1219 mm) shall be located outside the shower, flush and parallel to the control wall....
- Speakman Versatile Thermostatic ADA Handheld Combination System SM-5080-ADA
- Proline Drain: Quick Drain USA - Tub to Shower Conversion with Long Sweep 90 Drain Connection
-
Sec.36.304(b)(13)
(13) Rearranging toilet partitions to increase maneuvering space;
-
Toilet Rooms South (Briefing Theater)
Toilet Rooms South (Briefing Theater): jj. The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door opening force of...
-
Toilet Rooms North (Celebrity Spies)–Men [sic]
Toilet Rooms North (Celebrity Spies)–Men [sic]: dd. The force required to push or pull open the men's toilet room door is 10 lbf, which exceeds the maximum allowable door...
-
H26
H26. If there are 6 or more stalls in the restroom, is one of those stalls (in addition to the wider stall noted above) exactly 36 inches wide with an out swinging stall door that...
-
§ 36.304(b)(13)
(13) Rearranging toilet partitions to increase maneuvering space;
-
609.3 Spacing
EXCEPTION: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1½ inches (38 mm) minimum....
-
609.3 Spacing
EXCEPTION: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1 1/2 inches (38 mm) minimum....
-
609.3 Spacing
EXCEPTION: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1 1/2 inches (38 mm) minimum....