1013.3 Height. Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: 1. From the adjacent walking surfaces; 2. ...
Search Results "Riser Height"
-
1013.3 Height
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (280 mm) minimum and 18 inches (455 mm) maximum measured to the top of the surface from the ground or floor surface....
-
M303.2.4.1.2 Height
Between 9 inches (230 mm) and 27 inches (685 mm) above the floor, the knee clearance shall be permitted to reduce at a rate of 1 inch (25 mm) in depth for every 6 inches (150 mm) in height...
-
Height Requirements
The proposed rule included an exception from the height requirements in 309.3 for special equipment and electrical and communications systems receptacles....
-
Adjustable height protocol
Percentage of subjects that were able to attain a transfer under adjustable height protocol Height (in) % Subjects Adjustable Height % Subjects Side...
-
407.3.3.1 Height
407.3.3.1 Height....
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs.
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
M301.1 General
Diagnostic equipment that supports patients in a supine, prone, or side-lying position shall comply with M301. EXCEPTION: Examination chairs complying with M302 that recline to...
-
M301.2.3 Size
The size of the transfer surface shall comply with M301.2.3.1 or M301.2.3.2. The size of transfer surfaces shall be measured from center points of their opposing sides.
-
M301.2.3 Size (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface size for diagnostic equipment used in the supine, prone, or side-lying position of 30 inches wide and 15 inches deep minimum. (proposed...
-
5.2.1 Transfer Surface Size Recommendations for M301
5.2.1 Transfer Surface Size Recommendations for M301 Description: The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids...
-
5.2.1.1 Transfer Surface Width
5.2.1.1 Transfer Surface Width. The transfer surface should be 28 inches wide minimum for equipment used by patients in a supine, side-lying, or prone position.
-
5.2 Transfer Surface Size for Equipment Used by Patients in Supine, Prone, or Side-Lying Position
5.2 Transfer Surface Size for Equipment Used by Patients in Supine, Prone, or Side-Lying Position.
-
5.2.1 Transfer Surface Size
5.2.1 Transfer Surface Size
-
5.2.1.2 Transfer Surface Depth
5.2.1.2 Transfer Surface Depth. The transfer surface should be 17 inches deep minimum for all equipment used by patients in a supine, side-lying, or prone position with the exception...
-
5.2 Transfer Surface Size Recommendations
5.2 Transfer Surface Size Recommendations
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be...
-
Examples of access:
Exam table that lowers to 17-19 inches from the floor Many people find these tables easier to use. There are many ways to help people get access. See the [images]...
-
M301.4.1 Clearance in Base
[See subsections ...]
-
M301.2.2 Size
The transfer surface shall be 30 inches (760 mm) wide minimum and 15 inches (381mm) deep minimum. Advisory M301.2.2 Size. The size requirements in this section apply only to the...
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.