Accessible dwelling units with adaptable features shall be provided as required by Section 11B-233.3.1.2....
Search Results "Residential Dwelling Unit"
-
11B-224.7.2 Accessible dwelling units with adaptable features
-
11B-203.9 Employee workstations
Employee workstations shall be on an accessible route complying with Division 4. Spaces and elements within employee workstations shall only be required to comply with Sections...
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-607.4 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in bathtubs located in bathing facilities provided that reinforcement has been installed in walls and located...
-
Scope of Coverage
A number of comments were received on the issue of which types of dwelling units should be subject to the Act's accessibility requirements, and the number or percentage of dwelling units...
-
233.1 General
Group homes, halfway houses, shelters, or similar social service center establishments that provide either temporary sleeping accommodations or residential dwelling units that are subject...
-
18.1 Q. Is it necessary to provide usable doors when the door leads to an area of the dwelling that is not accessible, such as the door leading down to an unfinished basement...?
Within the dwelling unit, doors intended for user passage through the unit must meet the requirements for usable doors....
-
Number of Accessible Bathrooms
A number of comments were received on how many bathrooms in a dwelling unit should be subject to the Act's "usable" bathroom requirement....
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
Shower Spray Unit and Water: ADA Standard Section 608.6
Section 608.6 covers the current ADA Standards for the shower spray units and water in shower compartments.
-
1.1 Q. Are townhouses in non-elevator buildings which have individual exterior entrances required to be accessible?
(See the discussion of townhouses in the preamble to the Guidelines under Section 2--Definitions [Covered Multifamily Dwellings] at 56 FR 9481, March 6, 1991, or 24 CFR Ch. I, Subch....
-
Common Use Areas in Residential Facilities—Section 203.8 of the 2010 Standards
Section 203.8 of the 2010 Standards provides that, in residential facilities, common use areas that do not serve residential dwelling units required to provide mobility features are not...
-
4(5)
(5) Exterior deck, patio, or balcony surfaces are no more than 1/2 inch below the floor level of the interior of the dwelling unit, unless they are constructed of impervious material such...
-
5.1 Q...Would the first story of single-story dwelling units over the parking level be required to be accessible?
adopt and amplify the definition of ground floor found in HUD's regulation implementing the Fair Housing Act (see 24 CFR 100.201) to indicate that . . .where the first floor containing dwelling...
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.
-
1132A.3, Item 5
5. A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an...
-
1132A.3, Item 2
2. Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the...
-
4.34.5.1 DOORS
Doors shall not swing into the clear floor space required for any fixture.
-
1132A.3, Item 3
3. Swinging doors shall be capable of opening at least 90 degrees.