A ramp landing that is not level causes individuals using wheelchairs to tip backward or bottom out when the ramp is approached....
Search Results "Ramp Width"
Commonly Searched Documents
-
A4.8.4 Landings
-
404.2.3 Clear Width
404.2.3 Clear Width. Door openings shall provide a clear width of 32 inches (815 mm) minimum....
- Figure 1009.3.3 Handrails for Sloped Entry – Drawing from the U.S. Access Board
-
Re: When is a Curb Ramp a Ramp?
I leave it up to the AHJ to define curb heights in order to apply them to the definition of a curb ramp. Most of the time that provides a max height of 7". ...
-
D2. Clear Passage
Does at least one door or one side of a double leaf door at the accessible entrance provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
Width and Length: ADA Standard Section 1002.4.4.1
Wheelchair spaces shall provide a clear width of 30 inches (760 mm) minimum and a clear length of 48 inches (1220 mm) minimum measured to 9 inches (230 mm) minimum above the floor surface...
-
4e.
Does the ramp have a level landing at the top and bottom of each ramp section that is at least 60 inches long?...
-
Location at Marked Crossings [4.7.9]
The foot of a curb ramp must be contained within the crosswalk, where one is marked....
-
R409.1 General
Handrails required at ramps and stairways, and handrails provided on pedestrian circulation paths shall comply with R409. Advisory R409.1 General....
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
-
10.3.1(16)
(16) Where provided in below grade stations, escalators shall have a minimum clear width of 32 inches....
-
§ 38.159(c)(5) Slope
Ramps shall have the least slope practicable and shall not exceed 1:4 when deployed to ground level....
-
11B-402.2 Components
Accessible routes shall consist of one or more of the following components: walking surfaces with a running slope not steeper than 1:20, doorways, ramps, curb ramps excluding the flared...
- SafePath VulcanLanding™ Rubber Transition Ramp
-
Accessible Routes [§402]
Accessible Routes [§402] Components of accessible routes include walking surfaces, doorways, ramps, curb ramps, elevators, and, where permitted, platform lifts....
-
404.2.3 Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum.
-
11B-405.7.2.1
Top landings shall be 60 inches (1524 mm) wide minimum.
-
405.7.3 Length
The landing clear length shall be 60 inches (1525 mm) long minimum.
-
R407.6.3 Length
R407.6.3 Length. The landing clear length shall be 1.5 m (5.0 ft) long minimum.
-
405.7.3 Length
405.7.3 Length. The landing clear length shall be 60 inches (1525 mm) long minimum.