Wheelchair spaces shall comply with 802.1....
Search Results "Electric Vehicle Charging Space"
Commonly Searched Documents
-
Wheelchair Spaces, Companion Seats, and Designated Aisle Seats: ADA Standard Section 802
- Crystal Sauna
-
1009.5.2 Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer platform surface and shall...
-
Start of Play: ADA Standard Section 1007.3.1
A clear floor or ground space 48 inches (1220 mm) minimum by 60 inches (1525 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-1007.3.1 Start of play
A clear floor or ground space 48 inches (1219 mm) minimum by 60 inches (1524 mm) minimum with slopes not steeper than 1:48 shall be provided at the start of play....
-
11B-805.3.1 Wheelchair spaces
Where seating is provided in waiting rooms, at least 5 percent of the seating shall be wheelchair spaces complying with Section 11B-802.1....
-
F244.2.3.2 Parking Spaces
Where provided, parking spaces shall comply with F244.2.3.2....
-
1015.4 Turning Space
A turning space complying with 304.3 shall be provided within viewing areas....
-
1015.4 Turning Space
A turning space complying with 304.3 shall be provided within viewing areas....
-
T303 Handrails, Stanchions, and Handholds
[See subsections ...]
-
T214 Operable Parts
[See subsections ...]
-
T207 Handrails, Stanchions, and Handholds
[See subsections ...]
-
14. In § 38.93(d)(3)
§ 38.93 [Amended] 14. In § 38.93(d)(3), remove the period at the end of the paragraph and add the following words: “,ensuring compliance with section 37.42, where applicable.” in...
-
§ 37.197 Remanufactured OTRBs
[See subsections ...]
-
§ 38.23(b)(1) Design load
(1) Design load. The design load of the lift shall be at least 600 pounds. Working parts, such as cables, pulleys, and shafts, which can be expected to wear, and upon which the lift...
-
§ 38.29(d)
(d) Handrails and stanchions shall be sufficient to permit safe boarding, on-board circulation, seating and standing assistance, and alighting by persons with disabilities.
-
§ 38.27 Priority seating signs
[See subsections ...]
-
§ 38.159(b)(10) Platform movement
(10) Platform movement. No part of the platform shall move at a rate exceeding 6 inches/second (150 mm/sec) during lowering and lifting an occupant, and shall not exceed 12...
-
C. Visibility Through a Window
C. Visibility Through a Window. Care should be taken so that the lift does not obscure the vision of the person occupying the securement position.
-
§ 38.23(b)(12) Use by standees
(12) Use by standees. Lifts shall accommodate persons using walkers, crutches, canes or braces or who otherwise have difficulty using steps. The platform may be marked to indicate a...
-
§ 38.83(c)(1) Design load
(1) Design load. Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26...
-
§ 38.83(c)(7) Stowage
(7) Stowage. A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps or bridge plates, including portable ramps or bridges plates...
-
§ 38.159(b)(11) Boarding direction
(11) Boarding direction. The lift shall permit both inboard and outboard facing of wheelchair and mobility aid users.
-
§ 38.159(b)(4) Power or equipment failure
(4) Power or equipment failure. Platforms stowed in a vertical position, and deployed platforms when occupied, shall have provisions to prevent their deploying, falling, or folding...