Wheelchair spaces shall be 36 inches (915 mm) wide minimum. EXCEPTION: Wheelchair spaces located on raised platforms shall be permitted to be 32 inches (815 mm) wide minimum to a...
Search Results "Diagnostic Room"
-
M303.2.2 Width
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.2.4 Equipment Clearances
Where wheelchair spaces are entered from the rear and includes space beneath components, wheelchair spaces shall include knee and toe clearances complying with M303.2.4.1 for breast...
-
M303.3.2 Beveled (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes greater than ¼ inch but not greater than ½ inch would be required...
-
M303.3.1 Vertical (Section-by-Section Analysis)
The MDE NPRM proposed that for equipment with a change in level at the entry to the wheelchair space, level changes of up to ¼ inch high are permitted to be vertical. This provision...
-
M303.1 General (Section-by-Section Analysis)
This is an introductory section.
-
Knee & Toe Space [M303.2.4]
Knee & Toe Space [M303.2.4] Recommendation: The final subcommittee’s recommendations increased the overall knee and toe space to a minimum of 28 inches, from the initially...
-
M303.2.4 Knee and Toe Clearance
Wheelchair spaces shall include knee and toe clearance complying with M303.2.4. The depth of the wheelchair space shall include knee and toe clearance of 17 inches (430 mm) minimum...
-
M303.2.4.1 Toe Clearance
Toe clearance shall be provided at a height of 9 inches (230 mm) above the floor to a depth of 6 inches (150 mm) maximum.
-
M303.3.1 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical.
-
M303.3.2 Beveled
Changes in level between ¼ inch (6.4 mm) high and ½ inch (13 mm) high maximum shall be beveled with a slope not steeper than 1:2.
-
M303.2.4.2 Knee Clearance
Knee clearance shall be provided at a depth of 11 inches (280 mm) minimum and 25 inches (635 mm) maximum at 9 inches (230 mm) above the floor and at a depth of 8 inches (205 mm)...
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-809.10.8.2 Floor space
A floor space 30 inches (762 mm) minimum by 48 inches (1219 mm) minimum shall be provided centered on the lavatory.
-
11B-224.1.2 Guest room doors and doorways
[2010 ADAS] 224.1.2 Guest Room Doors and Doorways. ...
-
11B-224.1.2 Guest room doors and doorways
[2010 ADAS] 224.1.2 Guest Room Doors and Doorways. ...
-
15. Laundry rooms
Laundry rooms 4.32.6 If provided in the facility or at the site, at least one of each type of appliance provided in each laundry area, except that laudry rooms serving covered multifamily...
-
4.23.1 MINIMUM NUMBER
Bathrooms, bathing facilities, or shower rooms required to be accessible by 4.1 shall comply with 4.23 and shall be on an accessible route....
-
Feature 1 - Parking and Passenger Drop-Off Areas
The accessible parking space has an adjacent and parallel access aisle that provides needed room for a person to open the car door fully and then to stand with the aid of a walker or crutches...
-
Scoping [4.1.2(6), 4.1.3(11)]
Access is required to all toilet rooms and bathrooms provided for public or common use....
-
(3) Adjustability: Transfer Surface Intermediate Heights
Under the proposed rule, diagnostic equipment would be in compliance if it provided a low transfer height anywhere within the range of 17 inches minimum and 19 inches maximum....
-
11B-224 Transient lodging guest rooms, housing at a place of education and social service center establishments
[See subsections ...]
-
11B-224 Transient lodging guest rooms, housing at a place of education and social service center establishments
[See subsections ...]