The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
Search Results "Curb Ramp Top Landing"
Commonly Searched Documents
-
11B-1008.2.5.2 Elevated
-
11B-1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
4.10.4(2)
(2) Visual elements shall be at least 2‒1/2 in (64 mm) in the smallest dimension.
-
1.1.14 Flatness of ramp cross slope
per ramp....
-
§ 38.83(c)(5) Slope
Ramps or bridge plates shall have the least slope practicable....
-
f-viii
If the ramp or landing has a vertical drop-off on either side, is edge protection provided? [ADA Standards § 4.8.7] Yes No...
-
§ 36.304(e) Portable ramps
(e) Portable ramps. Portable ramps should be used to comply with this section only when installation of a permanent ramp is not readily achievable....
-
T402.5 Surfaces
Ramp and bridgeplate surface material shall comply with T302 and extend across the full width and length of the ramp or bridgeplate....
-
11B-405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12. Exception: Reserved....
-
11B-405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12. Exception: Reserved....
-
11B-405.2 Slope
Ramp runs shall have a running slope not steeper than 1:12. Exception: Reserved....
-
Visual Detection of Detectable Warning Materials by Pedestrians with Visual Impairments - Final Report
(Task Order 18 under Project DTFH61-01-C-00049) Authors: James Jenness & Jeremiah Singer May 24, 2006 Prepared for: Federal Highway Administration Washington,...
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
505.2 Where Required
Handrails shall be provided on both sides of stairs and ramps....
-
11B-810.2.3 Connection
constructed bus stop boarding and alighting areas shall provide a detectable transition between the boarding/alighting area and the roadway; the detectable transition shall consist of a curb...
-
§ 38.159(c)(7) Stowage
A compartment, securement system, or other appropriate method shall be provided to ensure that stowed ramps, including portable ramps stowed in the passenger area, do not impinge on a passenger's...
-
§ 38.23(b)(8) Platform entrance ramp
(8) Platform entrance ramp....
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
-
SECTION 1023 INTERIOR EXIT STAIRWAYS AND RAMPS
[See subsections ...]
-
11B-1008.2.5.3.2 Handrail height
The top of handrail gripping surfaces shall be 20 inches (508 mm) minimum and 28 inches (711 mm) maximum above the ramp surface....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....