In addition, this chapter includes technical requirements based on children’s dimensions and anthropometrics for drinking fountains, water closets, toilet compartments, lavatories and sinks...
Search Results "Compartment Width"
Commonly Searched Documents
-
11B-102 Dimensions for adults and children
-
§ 38.95(b)(6) Platform surface
The lift platform shall have a minimum clear width of 28 1/2 inches at the platform, a minimum clear width of 30 inches measured from 2 inches above the lift platform surface to 30 inches...
-
102 Dimensions for Adults and Children
In addition, this document includes technical requirements based on children's dimensions and anthropometrics for drinking fountains, water closets, toilet compartments, lavatories and sinks...
-
102 Dimensions for Adults and Children
In addition, this document includes technical requirements based on children's dimensions and anthropometrics for drinking fountains, water closets, toilet compartments, lavatories and sinks...
-
1003.2.13.2 Enclosed stairways
An enclosed stairway, to be considered part of an accessible means of egress, shall have a clear width of 48 inches (1219 mm) minimum between handrails and shall either incorporate an area...
- Redi Free® with Redi Base® Shower Pans
- Redi Free® with Redi Trench® Shower Pans
-
11B-603.2.3 Door swing
Clarifies that doors to accessible toilet compartments are allowed to encroach over required turning space without limitation. 11B-603.2.3 Door swing....
-
224.1.2 Guest Room Doors and Doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
F224.1.2 Guest Room Doors and Doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
224.1.2 Guest Room Doors and Doorways
Because of the social interaction that often occurs in lodging facilities, an accessible clear opening width is required for doors and doorways to and within all guest rooms, including those...
-
General: ADA Standard Section 307.1
Section 307.1 of the ADA Standards covers information in the current ADA Standards for protruding objects.
-
Protruding Objects: ADA Standard Section 204
Section 204 covers the scoping requirements of general exceptions for protruding objects in the most current ADA Standards
-
Protruding Objects: ADA Standard Section 307
Section 307 covers the current ADA Standards for protruding objects.
-
Transient Lodging Facilities: ADA Standard Section 206.5.3
Section 206.5.3 covers scoping requirements in the most current ADA Standards for accessible routes to transient lodging facilities.
-
11B-204 Protruding objects
[See subsections ...]
-
11B-307.1 General
Protruding objects shall comply with Section 11B-307.
-
11B-307 Protruding objects
[See subsections ...]
-
Building Entrance
At least one door at the accessible entrance must have a minimum clear width of 32 inches for a voter who uses a wheelchair or other mobility device to pass through the doorway....
-
Toilet Rooms North (Celebrity Spies)–Women [sic]
Toilet Rooms North (Celebrity Spies)–Women [sic]: ff. The force required to push or pull open the women's toilet room door is 10 lbf, which exceeds the maximum allowable door...
-
4.1.6(3)(e)(ii)
(ii) Where it is technically infeasible to install a required standard stall (Fig. 30(a)), or where other codes prohibit reduction of the fixture count (i.e., removal of a water...
-
§ 37.43(e)(2)(ii)
(ii) Costs associated with making restrooms accessible (e.g., grab bars, enlarged toilet stalls, accessible faucet controls);
-
Turnstiles and Security Gates at Entrances
Turnstiles and Security Gates at Entrances Businesses with narrow revolving turnstiles located at the entrance exclude people with disabilities unless accessible gates or passages...