[See subsections ...]
Search Results "Alternate Door"
Commonly Searched Documents
-
Remove post (increase clear width at double leaf doors)
-
I. Security
Is the security latch or bolt on the hall door mounted no higher than 48" above the floor so it is within the reach of persons who use wheelchairs and is it operable with one hand, without...
-
g-ii
Is the door hardware (e.g., lever, pull, push, panic bar) usable with one hand, without tight grasping, pinching, or twisting of the wrist, to allow people who may not be able to easily...
- LaCantina Doors - Contemporary Clad Industrial
-
Shower Compartments
Alternate roll-in showers are 36 inches wide by 60 inches long minimum, and have a 36-inch minimum wide opening on the long side of the compartment....
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
§ 35.150(b)
(b) * * *
-
4.21.4 Grab Bars
Grab bars complying with 4.26 shall be provided as shown in Fig. 37.
-
4.21.4 GRAB BARS
Grab bars complying with 4.26 shall be provided as shown in Fig. 37. Figure 37 Grab Bars at Shower Stalls
-
§ 35.150(b) Methods
(b) Methods.
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
E. Key Reach Range
If there is key card controlled door hardware on building entrances, is the key card reader positioned so persons who use wheelchairs may approach and operate the opener (48" high maximum...
-
9.5.2(2)(b)
(b) sleeping space for homeless persons as provided in the scoping provisions of 9.1.2 shall include doors to the sleeping area with a minimum clear width of 32 in (815 mm) and maneuvering...
-
Visual Notification Devices
Visual Notification Devices Care must be taken that notification devices intended to signal a door knock or bell are separately wired....
-
4.1.6(3)(e)(ii)
., removal of a water closet in order to create a double-wide stall), either alternate stall (Fig.30(b)) may be provided in lieu of the standard stall....
-
D2
Does at least one door or one side of a double leaf-door provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
Toilet Compartment Access
Your figure shows two compartment door approach options, the one shown in Figure 604.8.1.2, and an alternate figure which is identical except that the door is hinged on the opposite side...
-
Study Goals
Study Goals To understand the usability of alternative formats; To identify characteristics of effective tactile graphics, maps, models, and wayfinding; To determine user preferences...
- Motorized Lift & Slide Door System by Panda
-
Inventory Control Devices
Inventory Control Devices It is important that inventory control or security devices not obstruct required maneuvering clearances at doors....