In the MDE NPRM the Access Board proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as...
Search Results "Telecommunications Equipment"
Commonly Searched Documents
-
M302.2.5 Unobstructed Transfer (Section-by-Section Analysis)
-
M303.3.3.5 Handrails
Ramps with a rise greater than 6 inches (150 mm) shall provide handrails on each side.
-
M303.3.3.3 Clear Width
The clear width of ramp runs shall be 36 inches (915 mm) minimum.
-
M303.3.3.1 Running Slope
Ramp runs shall have a running slope not steeper than 1:12.
-
Chapter M1 Application and Administration
[See subsections ...]
- Medical Accessibility LLC
- SPORTS 'N SPOKES
-
Attachment D: HUMBOLDT COUNTY POLICE DEPARTMENT POLICY STATEMENT REGARDING EFFECTIVE COMMUNICATION WITH PEOPLE WHO ARE DEAF OR HARD OF HEARING
nondisabled person would have access to a telephone, officers must provide persons who are deaf or hard of hearing the opportunity to place calls using a text telephone (TTY, also known as a telecommunications...
-
Figure M3: Overview of M302 Diagnostic Equipment for Use by a Patient in a Seated Position
[See subsections ...]
-
Transfer Surface (M301.2 and M302.2)
The transfer surface is the part of the diagnostic equipment onto which patients who use mobility devices or aids transfer when moving onto and off of the equipment (see defined terms in...
-
§ 1194.23 Telecommunications products
§ 1194.23 Telecommunications products....
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with portable patient lifts and, when in use with such lifts, shall comply with M302.4.1 or M302.4.2. ...
-
M302.4 Lift Compatibility
Diagnostic equipment shall be usable with a patient lift and shall comply with M302.4.1 or M302.4.2....
-
M302.4 Lift Compatibility (Section-by-Section Analysis)
The MDE NPRM proposed to require that diagnostic equipment used by patients in the seated position be usable with a patient lift and comply with either the proposed clearance in base (proposed...
-
Tips for Weighing People Using an Accessible Scale
By June Isaacson Kailes, Associate Director Harris Family Center for Disability and Health Policy Western University of Health Sciences, Pomona, California Update -...
-
M302.2.1 Adjustability (Section-by-Section Analysis)
The MDE NPRM proposed a transfer surface height range for diagnostic equipment used by patients in a seated position of 17 inches minimum and 19 inches maximum....
-
Physical Barriers
This very common barrier includes inaccessible parking, uneven pathways to health care offices, inaccessible medical equipment, narrow doorways, etc....
-
M305.3.1.3 Vertical Position
The length of the gripping surface on vertical standing supports shall be 18 inches (455 mm) minimum.
-
M305.3.2.2 Vertical Position
The height of the lowest end of the gripping surface on vertical standing supports shall be 34 inches (865 mm) minimum and 37 inches (940 mm) maximum above the standing surface.
-
M303.2.4.1 Breast Platforms
Wheelchair spaces beneath breast platforms shall comply with M303.2.4.1.
-
M303.2.4.1.1 Depth
Wheelchair spaces shall include knee and toe clearance 25 inches (635 mm) deep minimum and 28 inches (710 mm) deep maximum.
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair...
-
5.8.2 Knee and Toe Clearance Under Breast Platform
5.8.2 Knee and Toe Clearance Under Breast Platform. The overall knee and toe space should be increased to a minimum of 28 inches deep, from the initially proposed 25 inch absolute...