The Board has not revised the minimum dimensions for the clear floor space at water closets....
Search Results "Swing Clear Hinge"
-
Water Closet Clear Floor Space in Toilet Compartments
-
4.3.5.3 180-degree turn around an obstacle
Figure 4-6: Accommodation model depicting the minimum clear width required by users of manual wheelchairs, powered wheelchairs and scooters to complete a 180-degree turn around an obstacle...
-
R302.4 Passing Spaces
Where the clear width of pedestrian access routes is less than 1.5 m (5.0 ft), passing spaces shall be provided at intervals of 61 m (200.0 ft) maximum....
- Pilot Rock CSL-6 and CSL-8 Car Stop
- Landscape Forms Inc. Parc Vue Trash Receptacle
- Magnuson Group MECORA Outdoor Waste Receptacle
-
11B-808.3 Clear floor space
Each jury box and witness stand shall have, within its defined area, clear floor space complying with Section 11B-305....
-
4.6.5 Slope
The slope of the clear floor or ground space required by section 4.6.4 shall not exceed 1:48 (2 percent) in any direction. Exception....
-
5.3.2.3 Slope
The slope of the turning space and clear floor or ground space surface shall not be steeper than 1:48 (2 percent) in all directions....
-
4.1.5 Slope
The slope of the surface of the clear floor or ground space around a picnic table shall not exceed 1:48 (2 percent) in any direction. Exception....
-
T502.4 Doorways with Steps on Over-the-Road Buses
On over-the-road buses, doorways with steps shall provide an opening with a clear width of 30 inches (760 mm) minimum. Exceptions: 1....
-
Plan 2B: 13-Foot Wide Accessible Guest Room
); • Recessed alternate roll-in shower location permits shorter rear grab bar at water closet (section 604.5.2); • Circular turning space in room (section 603.2.1); • Required clear...
-
11B-224.1.2 Guest room doors and doorways
In transient lodging facilities, bathrooms doors shall be either sliding or hung to swing in the direction of egress from the bathroom....
-
Clear Floor Space [4.34.2] and Reach Ranges [4.34.3]
Clear Floor Space [4.34.2] and Reach Ranges [4.34.3] Either a forward approach or a parallel approach to the ATM must be provided....
-
Alterations and water closet clearances in single-user toilet rooms with in-swinging doors. (Section-by-Section Analysis)
The 1991 Standards do not allow an in-swinging door in a toilet or bathing room to overlap the required clear floor space at any accessible fixture....
-
Ground-Level Accessible Routes
Ground-Level Accessible Routes A ground-level accessible route connects play components at ground level. 60 inches (1525 mm) minimum clear width 1:16 maximum slope ...
-
805.3 Clear Floor or Ground Space
805.3 Clear Floor or Ground Space. A clear floor space complying with 305 shall be provided on each side of the bed....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADA Standards] 805.3 Clear Floor or Ground Space....
-
11B-805.2.2 Beds
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of the beds. [2010 ADA Standards] 805.3 Clear Floor or Ground Space....
- Pilot Rock Varmint Defiant Trash Can Cover
-
Single-User Toilet Rooms: Side Transfer Space
Clear floor space should be centered at lavatories. This clear floor space, which can overlap space required at water closets, must extend 17 to 19 inches below the lavatory....
-
Clear Width of Circulation Paths and Maneuvering Clearances at Wheelchair Spaces
These clearances were in addition to the requisite 30 inch by 48 inch minimum clear floor space for each wheelchair space....
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...
-
11B-306.3.3 Minimum required depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (279 mm) deep minimum at 9 inches (229 mm) above the finish floor...