A curb ramp shall have a detectable warning complying with 705....
Search Results "Ramp Run"
Commonly Searched Documents
-
406.8 Detectable Warnings
-
11B-406.5.12 Detectable warnings
A curb ramp shall have a detectable warning complying with 705....
-
11B-406.5.12 Detectable warnings
A curb ramp shall have a detectable warning complying with 705....
-
11B-406.5.12 Detectable warnings
A curb ramp shall have a detectable warning complying with 705....
-
T404.3 Ramps and Bridgeplates
platform is greater than 2 inches (51 mm) horizontally or 5/8 inch (16 mm) vertically when measured at 50 percent passenger load with the vehicle at rest, non-rail vehicles shall provide ramps...
-
T402.7 Edge Guards
Ramps and bridgeplates shall provide edge guards continuously along each side of the ramp or bridgeplate to within 3 inches (75 mm) of the end of the ramp or bridgeplate that is deployed...
-
Islands [§406.7]
Islands [§406.7] A 48” min. long separation is necessary between curb ramps so that people using wheelchairs can clear one ramp before negotiating the next....
-
R304.3.1 Turning Space
A turning space 1.2 m (4.0 ft) minimum by 1.2 m (4.0 ft) minimum shall be provided at the bottom of the curb ramp and shall be permitted to overlap other turning spaces and clear spaces....
-
Can ramps be portable or provided after construction as an adaptation?
All required ramps and curb ramps must be permanent and installed at the time of construction or alteration with few exceptions....
-
Recreational Boating Facilities: ADA Standard Section 206.2.10
Section 206.2.10 covers scoping requirements in the most current ADA Standards for accessible routes to recreational boating facilities
-
Detectable Warnings on Curb Ramps
[See subsections ...]
- Designing Sidewalks and Trails for Access, Part II of II: Best Practices Design Guide
-
11B-405.7.5 Doorways
Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches (76 mm)....
-
11B-405.7.5 Doorways
Doors, when fully open, shall not reduce the required ramp landing width by more than 3 inches (76 mm)....
-
T402.2 Design Load
Ramps and bridgeplates 30 inches (760 mm) or more in length shall be designed to support a load of 600 pounds (273 kg) minimum, placed at the centroid of the ramp distributed over an area...
-
9 [§ 4.7.5]
9 [§ 4.7.5] Curb ramps either have flared sides or vertical edges called returned curbs....
-
11B-406.1 General
Curb ramps, blended transitions and islands on accessible routes shall comply with Section 11B-406....
-
11B-406.1 General
Curb ramps, blended transitions and islands on accessible routes shall comply with Section 11B-406....
-
11B-406.1 General
Curb ramps, blended transitions and islands on accessible routes shall comply with Section 11B-406....
-
T402.1 General
Ramps and bridgeplates shall comply with T402. Ramps and bridgeplates shall be permitted to fold or telescope....
-
11B-206.2.10 Recreational boating facilities
Boat slips required to comply with Section 11B-235.2 and boarding piers at boat launch ramps required to comply with Section 11B-235.3 shall be on an accessible route....
-
4 [§ 4.7.2]
To measure the gutter slope, place the level in the same position as the arrow in the illustration, with one end where the gutter meets the ramp and the other end towards the street....
-
Cross Slope
Comments indicated that specifications for cross slope (1:48 maximum) are not referenced in the curb ramp section. Response....
-
§ 38.83(c)(1) Design load
Ramps or bridge plates 30 inches or longer shall support a load of 600 pounds, placed at the centroid of the ramp or bridge plate distributed over an area of 26 inches, with a safety factor...