capabilities of the materials and processes, David Ballast generally recommends a tolerance of 0.5% in the cross slope direction and 1.0% in the direction of travel for concrete or asphalt ramps...
Search Results "Ramp Length"
Commonly Searched Documents
-
Q5.) What dimensions and conditions can practitioners reasonably consider to be compliant when the conditions, as constructed, do not meet the technical requirements exactly and there are no official, published, industry-developed tolerances?
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
T402.6 Clear Width
The clear width of ramps and bridgeplates shall be 30 inches (760 mm) minimum....
-
Priority 1: Approach & Entrance
Word Fillable Form (1.5MB) Word Non-Fillable Form (1.3MB) PDF Non-Fillable Form (0.8MB)
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
Rough Form and Foundation Inspection
areas, and other site arrival points) to ensure correct accessible slopes (5% running slope and 2.08% cross slope). 11B-403 Verify forms for sidewalks, ramps...
-
Rough Form and Foundation Inspection
areas, and other site arrival points) to ensure correct accessible slopes (5% running slope and 2.08% cross slope). 11B-403 Verify forms for sidewalks, ramps...
-
d-iv
Are the handrails mounted 34 to 38 inches above the ramp surface? [ADA Standards § 4.8.5] Yes No...
-
f-vii
Are the handrails mounted 34 to 38 inches above the ramp surface? [ADA Standards § 4.8.5] Yes No...
-
4c.
Are the handrails mounted between 34 and 38 inches above the ramp surface? [ADA Stds 4.8.5] Yes _____ No _____...
-
1.2.3 Landings
Both measurements of ramp landings as described in Section 1.1.15 should not exceed a plus tolerance of 0.5%....
-
4.1.6(1)(b)
requirements) requiring major structural changes are planned or installed where none existed previously, then a means of accessible vertical access shall be provided that complies with 4.7, Curb Ramps...
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by 404.2.4 and 404.3.2 shall be permitted to overlap the required landing area....
-
A4.8.5 Handrails
The requirements for stair and ramp handrails in this guideline are for adults....
-
A4.8.5 HANDRAILS
The requirements for stair and ramp handrails in this standard are for adults....
-
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces
5.9.2.2 Standing Supports on Dual Ramped Entry Raised Platforms with Wheelchair Spaces....
- Designing Sidewalks and Trails for Access, Part I of II: Review of Existing Guidelines and Practices
-
DSA Drawing 11B-406-4C Curb Ramp Adjoining a Parking Access Aisle with No Gutter (2016 CBC)
Requires the Premium User plan or above. (Login or upgrade your account!)
-
§ 38.73(d)(4) Exception
practicable to meet the horizontal or vertical requirements of paragraphs (d) (1), (2) or (3) of this section, platform or vehicle devices complying with §38.83(b) or platform or vehicle mounted ramps...