Patient bedrooms or resident sleeping rooms added or altered as part of a planned renovation of an entire wing, a department, or other discrete area of an existing medical facility shall...
Search Results "MDE: Medical Diagnostic Equipment"
Commonly Searched Documents
-
11B-223.1.1.1 Area alterations
-
11B-223.1.1.1 Area alterations
Patient bedrooms or resident sleeping rooms added or altered as part of a planned renovation of an entire wing, a department, or other discrete area of an existing medical facility shall...
-
11B-223.1.1.1 Area alterations
Patient bedrooms or resident sleeping rooms added or altered as part of a planned renovation of an entire wing, a department, or other discrete area of an existing medical facility shall...
-
5.2.2.2 Transfer Surface Depth
The transfer surface should be 17 inches deep minimum for equipment used by patients in a seated position....
-
5.2.2.1 Transfer Surface Width
The transfer surface should be 21 inches wide minimum for examination chairs and other equipment used by patients in a seated position....
-
Maximum Leave Policies
other reasonable accommodations may enable the employee to return to work sooner than the employee anticipates, as long as those accommodations would be consistent with the employee's medical...
-
7. May an employer require an individual to go to a health care professional of the employer's (rather than the employee's) choice for purposes of documenting need for accommodation and disability?
Documentation is insufficient if it does not specify the existence of an ADA disability and explain the need for reasonable accommodation.(33) Any medical examination conducted by the...
-
5.2.3 Transfer Surface Measurement Recommendation for M301 and M302
Figure 5.2.3 below indicates how these width and depth dimensions are measured for MDE used by patients in supine, prone, or side-lying positions (M301) and the seated position (M302)...
-
11B-805 Medical care and long-term care facilities
SECTION 11B-805 Medical care and long-term care facilities 11B-805.6 Handwashing fixtures, lavatories and sinks....
-
M305.4 Leg Supports
Leg supports shall provide a method of supporting, positioning, and securing the patient’s legs.
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
M301.2.3 Size
The size of the transfer surface shall comply with M301.2.3.1 or M301.2.3.2. The size of transfer surfaces shall be measured from center points of their opposing sides.
-
5.2.1 Transfer Surface Size
5.2.1 Transfer Surface Size
-
5.2 Transfer Surface Size Recommendations
5.2 Transfer Surface Size Recommendations
-
M301.4.1 Clearance in Base
[See subsections ...]
-
M301.2 Transfer Surface
A transfer surface shall be provided and shall comply with M301.2.
-
Staff Training
Staff Training Ongoing staff training is essential to ensure that accessible equipment (particularly pool lifts) and pool facilities are available whenever a pool is open....
- Sargent 7800 Mortise Lock with Push/Pull Trim Hardware
- GPK UPPERTONE Unassisted Muscle Strengthening System for Quadriplegics
-
M302.4.1 Clearance in Base
The base of the diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
- RESNA Standards Committee on Inclusive Fitness
-
Section 1630.14(c) Examination of Employees
Section 1630.14(c) Examination of Employees This provision permits employers to make inquiries or require medical examinations (fitness for duty exams) when there is a need to determine...
-
5.2.2.1 Transfer Surface Width Recommendations for M302
5.2.2.1 Transfer Surface Width Recommendations for M302 The Committee recommends 21 inches for the minimum width of the transfer surface of examination chairs and other equipment primarily...
- NuStep T4r Recumbent Cross Trainer