Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...
Search Results "Low Energy Door"
Commonly Searched Documents
-
Re: 404.2.4.3 Recessed Doors and Gates
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19....
-
(1)(e)
Door latches and hardware should be operable with one hand and should not require tight grasping, pinching, or twisting of the wrist....
-
Are doors or gates to employee work areas required to comply?
Entry doors or gates to employee work areas are required to meet applicable requirements, including those for maneuvering clearance, on the exterior, but not the interior....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
11B-604.8.1.1.2 Maneuvering space with side-opening door....
-
Duration: ADA Standard Section 408.3.2.2
Section 408.3.2.2 covers the current ADA Standards for the duration of swinging doors on limited-use/limited-application elevator.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
D4. Door Clearance
On the pull side of the door, is there at least 18 inches clearance provided to the side of the latch if the door is not automatic or power-operated?...
-
Jeanne Halloin, IES. Existing Standards and Design Guidance
entrances Handle locations should be consistent Ramps (slide 5) Route of Travel (slide 6) Rooms and Spaces (slide 7) Additional comments: Low...
- Haws Barrier-Free Chilled Dual Wall Mount Fountain H1011.8HO
- Haws Barrier-Free Chilled Dual Wall Mount Fountain H1117.8
- Haws Barrier-Free Chilled Wall Fountain H1107.8
- Haws Barrier-Free Chilled Dual Wall Mount Fountain H1119.8
-
(4) Doors to public and common use areas
The final Guidelines continued to provide that on accessible routes in public and common use areas, and for primary entry doors to covered units, doors that comply with ANSI 4.13 meet the...
- CS Pocket Insert Track Demo
-
2.2 Entrances
Can the accessible entrance be used independently, or is the door heavy or usually locked? Is the entrance door at least 32 inches wide?...
-
Maneuvering Clearances: ADA Standard Section 404.2.4
Section 404.2.4 covers the current ADA Standards for maneuvering clearances at doors, doorways, and gates.
-
A4.10.6 Door Protective and Reopening Device
The required door reopening device would hold the door open for 20 seconds if the doorway remains obstructed. After 20 seconds, the door may begin to close....
-
A4.10.6 DOOR PROTECTIVE AND REOPENING DEVICE
The required door reopening device would hold the door open for 20 seconds if the doorway remains unobstructed. After 20 seconds, the door may begin to close....
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor.