The following ABA requirements apply to recipients of federal financial assistance from DOT: 5.1.1 ATBCB Final Rule, 36 CFR part 1190, Minimum Guidelines and Requirements for Accessible...
Search Results "Evacuation Assistance"
-
5.1 Architectural Barriers Act (ABA).
-
Overhead Track Lifts
Overhead Track Lifts Overhead track lifts include ceiling mounted lifts and lifts mounted on a frame supported from the floor.
-
§382.51(a)(2)
(2) With respect to any situation in which boarding and deplaning by level-entry loading bridges or accessible passenger lounges to and from an aircraft is not available, you must...
-
Using Patient Lifts
Using Patient Lifts Medical providers may need a lift in order to transfer some patients safely onto an exam table. Patient lifts may move along the floor or be mounted on an...
-
404.3.5 Controls
Manually operated controls shall comply with 309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing.
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum...
-
404.3.5 Controls
Manually operated controls shall comply with 309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing.
-
404.3.6 Break Out Opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (815 mm) minimum...
-
§27.3 Applicability.
[44 FR 31468, May 31, 1979, as amended at 56 FR 45621, Sept. 6, 1991; 68 FR 51390, Aug. 26, 2003; 80 FR 46513, Aug. 5, 2015]
-
404.3.5 Controls
404.3.5 Controls. Manually operated controls shall comply with 309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing.
-
404.3.6 Break Out Opening
404.3.6 Break Out Opening. Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32...
-
11B-404.3.5 Controls
Manually operated controls shall comply with Section 11B-309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory...
-
C205.2 WCAG Conformance
User interface components and content of platforms and applications shall conform to Level A and Level AA Success Criteria and Conformance Requirements specified for Web pages in...
-
A4.1.3(9)
A4.1.3(9) Supervised automatic sprinkler systems have built in signals for monitoring features of the system such as the opening and closing of water control valves, the power...
-
6. RECEIVERS AND COUPLERS: RECOMMENDATIONS
6. RECEIVERS AND COUPLERS: RECOMMENDATIONS When hard of hearing people use an ALS, they are not usually concerned with the characteristics of the installation and transmission...
-
11B-404.3.5 Controls
Manually operated controls shall comply with Section 11B-309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum...
-
11B-404.3.5 Controls
Manually operated controls shall comply with Section 11B-309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum...
- Oval Window Audio Portable InfoLoop Hearing System
-
382.99 What agreements must carriers have with the airports they serve?
Foreign carriers would have two years from the effective date of the rule to ensure that the boarding assistance called for in this rule was actually being provided....
-
Inclusive Event Procedures for Emergencies
Edition 1 – October 2017 By June Isaacson Kailes Recommended Citation: Kailes, J.I. (2017) Inclusive Event Procedures for Emergencies, Edition I, http://www.jik.com...
-
Section 36.303(g)(4) Minimum Requirements for Audio Description Devices
However, the Department noted at proposed § 36.303(g)(3)(ii)(B) that “[a] movie theater may comply with this requirement by using receivers it already has available as assistive listening...