When somebody presses the Pushbutton Transmitter, it sends a radio signal to the Visit receiver(s) for alerting. Choose how to be alerted from flashes, sounds and vibrations....
Search Results "Elevator Signal Timing"
Commonly Searched Documents
- Pushbutton Transmitter (BE1240)
-
4.10.6* DOOR PROTECTIVE AND REOPENING DEVICE
Elevator doors shall open and close automatically....
-
Leveling: ADA Standard Section 409.4.4
Section 409.4.4 covers the ADA Standards for the self-leveling feature in private residence elevators.
-
11B-407.4.3 Platform to hoistway clearance
The clearance between the car platform sill and the edge of any hoistway landing shall be 1¼ inch (32 mm) maximum.
-
11B-411.4.7.2 Location
Raised characters or symbols and Braille designations shall comply with Section 11B-407.4.7.1.2.
-
11B-407.4.8.2 Audible indicators
Audible indicators shall comply with Section 11B-407.4.8.2.
-
11B-409.4.4 Leveling
Each car shall automatically stop at a floor landing within a tolerance of ½ inch (12.7 mm) under rated loading to zero loading conditions.
-
11B-407.2.1.1 Height
Call buttons and keypads shall be located within one of the reach ranges specified in Section 11B-308, measured to the centerline of the highest operable part. Exception:...
-
11B-411.2.1.3 Arrangement
Hall call console arrangement of required features shall comply with Section 11B-411.2.1.3.
-
11B-411.2.1 Hall call consoles
Hall call consoles shall comply with Sections 11B-411.2.1 and 11B-309.
-
11B-411.2.1.4 Additional features
Hall call console additional features, if provided, shall comply with Sections 11B-309 and 11B-411.2.1.4.
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
409.4.6.1 Size
Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
409.4.6.1 Size
409.4.6.1 Size. Control buttons shall be 3/4 inch (19 mm) minimum in their smallest dimension.
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
11B-409.4.6.1 Size
Control buttons shall be ¾ inch (19.1 mm) minimum in their smallest dimension.
-
11B-409.4.6.2 Location
Control panels shall be on a side wall, 12 inches (305 mm) minimum from any adjacent wall.
-
1008.2.1 Ground Level and Elevated Play Components
1008.2.1 Ground Level and Elevated Play Components....
-
11B-407.2.1.3 Clear floor or ground space
The clear floor or ground space required at elevator call buttons must remain free of obstructions including ashtrays, plants, and other decorative elements that prevent wheelchair users...
-
4.1.6(3)(c)(iii)
(iii) Equivalent facilitation may be provided with an elevator car of different dimensions when usability can be demonstrated and when all other elements required to be accessible comply...
-
1008.2.1 Ground Level and Elevated Play Components
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided no more than 25 percent of the...