No, audible (and visible) signals required for elevators must function automatically at all times an elevator is operational....
Search Results "Elevated Play Component"
Commonly Searched Documents
-
Can audible signals for an elevator operate only when needed by a passenger who needs them through activation of dedicated “accessibility” control?
-
Symbols: ADA Standard Section 407.4.7.1.3
Section 407.4.7.1.3 covers the current ADA Standards for the designation and indicator symbols on elevator car control buttons.
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in elevator cars....
-
407.4.7 Designations and Indicators of Car Controls
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7....
-
407.4.7 Designations and Indicators of Car Controls
EXCEPTION: In existing elevators, where a new car operating panel complying with 407.4.7 is provided, existing car operating panels shall not be required to comply with 407.4.7....
-
1008.2.4.1 Ground Level
In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1120 mm) minimum, if at least one turning space complying with...
-
1008.2.4.1 Ground Level
In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1120 mm) minimum, if at least one turning space complying with...
-
1008.2.4.1 Ground Level
In play areas less than 1000 square feet (93 m²), the clear width of accessible routes shall be permitted to be 44 inches (1120 mm) minimum, if at least one turning space complying with...
-
11B-1008.2.4.1 Ground level
In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1118 mm) minimum, if at least one turning space complying with...
-
11B-1008.2.4.1 Ground level
In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1118 mm) minimum, if at least one turning space complying with...
-
11B-1008.2.4.1 Ground level
Exceptions: In play areas less than 1000 square feet (93 m2), the clear width of accessible routes shall be permitted to be 44 inches (1118 mm) minimum, if at least one turning space...
-
Hall Signals: ADA Standard Section 407.2.2
Section 407.2.2 covers the current ADA Standards for elevator hall signals.
-
Size: ADA Standard Section 407.4.6.2.1
Section 407.4.6.2.1 covers the current ADA Standards for the size of the elevator car control buttons.
-
Arrangement: ADA Standard Section 407.4.6.2.2
Section 407.4.6.2.2 covers the current ADA Standards for the arrangement of the elevator car control buttons.
-
Buttons: ADA Standard Section 407.4.7.1
Section 407.4.7.1 covers the current ADA Standards for designations and indicators on elevator car control buttons.
-
11B-407.4.6.2.3 Illumination
Car control buttons shall be illuminated.
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.
-
11B-407.2.2 Hall signals
Hall signals, including in-car signals, shall comply with Section 11B-407.2.2.
-
11B-407.4.6.2.4 Operation
Car control buttons shall be activated by a mechanical motion that is detectable.
-
11B-407.4.10.3 Structural strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the support rail, fastener, mounting...
-
11B-407.4.10.1 Location
Clearance between support rails and adjacent surfaces shall be 1½ inches (38 mm) minimum. Top of support rails shall be 31 inches (787 mm) minimum to 33 inches (838 mm) maximum above...
-
11B-407.4.10.2 Surfaces
Support rails shall be smooth and any surface adjacent to them shall be free of sharp or abrasive elements.
-
11B-407.4.7.1 Buttons
Car control buttons shall comply with Section 11B-407.4.7.1.
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.