In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
Search Results "Door Signal Device"
Commonly Searched Documents
-
11B-206.5.3 Transient lodging facilities
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
Smooth Surface
Exceptions from this requirement are recognized for sliding doors (Exception 1), certain tempered glass doors without stiles (Exception 2), doors and gates that do not extend to within 10...
- Freedom Scientific Focus 14 Blue Ultra-Portable Braille Interface Device
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
409.3.1 Power Operation
Elevator car and hoistway doors and gates shall be power operated and shall comply with ANSI/BHMA A156.19 (1997 or 2002 edition) (incorporated by reference, see "Referenced Standards" in...
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
1132A.8 Hand-activated door hardware
Hand-activated door latching, locking and opening hardware shall be centered between 30 inches (762 mm) and 44 inches (1118 mm) above the floor....
-
Legal standard for other power-driven mobility devices. (Section-by-Section Analysis)
Legal standard for other power-driven mobility devices....
-
Use of Segways® and Similar Devices by Individuals with a Mobility Impairment in GSA-Controlled Federal Facilities
Policy Summary: The General Services Administration (GSA) recognizes that some persons with mobility impairments are utilizing the Segway® Personal Transporter (Segway) and similar devices...
- Intro to Door Hardware: Von Duprin Exit Devices 101
-
Wheelchairs
Wheelchairs Carriers must permit storage in the cabin of wheelchairs or components of wheelchairs, including folding, collapsible, or breakdown battery-powered wheelchairs [Sec....
-
Battery-powered Wheelchairs
Battery-powered Wheelchairs Carriers must accept a passenger’s battery-powered wheelchair, including the battery, as checked baggage unless baggage compartment size and aircraft...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
1132A.3, Item 5
A pair of doors, manual or automatic, must have at least one leaf which provides a clear width of not less than 32 inches (813 mm), measured with the door positioned at an angle of 90 degrees...
-
4.1.2(7)
(7) Doors: (a) At each accessible entrance to a building or facility, at least one door shall comply with 4.13....
-
11B-213.3.1.2 Toilet compartments with urinal compartments
At all compartments not required to comply with Section 11B-604.8 or Section 11B-605.5, compartment doors shall be in-swinging and self-closing....
-
Door Clear Width
Door Clear Width Open the door 90 degrees, measure from the face of the door to the edge of the door stop....
-
§382.129 What other requirements apply when passengers' wheelchairs, other mobility aids, and other assistive devices must be disassembled for stowage?
[See subsections ...]
-
§382.131 Do baggage liability limits apply to mobility aids and other assistive devices?
With respect to transportation to which 14 CFR part 254 applies, the limits to liability for loss, damage, or delay concerning wheelchairs or other assistive devices provided in part 254...
-
Entrances
space beyond the latch side of the door....
-
Are spring hinges and gravity hinges considered “closers” in determining the size of maneuvering clearances?
Some approaches require additional maneuvering clearances when a door or gate is equipped with a closer because of the additional force that must be counteracted in proceeding through doors...
-
Standard Stall
The clearances required for stall doors are different than those specified for conventional passage doors and gates in 4.13.6 since partition doors are generally lighter and easier to open...