No, a 32-inch door would not provide a sufficient clear opening to meet the requirement for usable doors....
Search Results "Door Operator"
-
16.1 Q. Will a standard hung 32-inch door provide sufficient clear width to meet the requirements of the Fair Housing Act?
-
Guestroom Doors
Guestroom Doors Common Problem: Doors and doorways into and within all guestrooms and suites, including bathroom doors and doorways, do not allow 32 inches of clear opening width....
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
In a wheelchair accessible compartment with a door located in the front wall or partition (facing the water closet), either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide...
-
11B-604.8.1.1.3 Maneuvering space with end-opening door
11B-604.8.1.1.3 Maneuvering space with end-opening door....
-
Closers
Closers Automated door closing is addressed by the ANSI/BHMA standards....
-
D3. Door Hardware
Is the door hardware (e.g., lever, pull, panic bar) usable with one hand without tight grasping, pinching, or twisting of the wrist?...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
G. Door Hardware
Is the door hardware (levers, pulls, panic bars, etc.) on all entry doors to accessible guestrooms and other passage doors within the room usable with one hand, without tight grasping, pinching...
-
A. Entry Doors
Do entry doors, connecting room doors, and interior doors (except doors to shallow closets) into and within all guestrooms and suites allow 32" clear passage width so persons who use wheelchairs...
-
205 Operable Parts, F205 Operable Parts
205 Operable Parts F205 Operable Parts These sections require operable parts located on accessible elements and accessible routes and in accessible rooms and spaces to comply with the...
-
Horton Automatics EasyAccess® Series 7100 for ADA Low Energy Applications
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Door Opening Force [4.13.11]
[See subsections ...]
-
407.8.3.2.1 Operable Part Height for ICT with Obstructed Forward Reach
The height of the operable part shall conform to Table 407.8.3.2.1....
-
11B-206.5.3 Transient lodging facilities
In transient lodging facilities, entrances, doors, and doorways providing user passage into and within guest rooms that are not required to provide mobility features complying with Section...
-
1132A.3, Item 1
Doors shall not be less than 6 feet 8 inches (2032 mm) in height....
-
1132A.3, Item 1
Doors shall not be less than 6 feet 8 inches (2032 mm) in height....
-
Door King Inc. 6400 In-Ground Gate Operators Video
Requires the Registered User plan or above. Login!
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
1132A.3, Item 2
Swinging doors shall provide a net clear opening width of not less than 32 inches (813 mm), measured with the door or doors positioned at an angle of 90 degrees from the closed position....
-
Doors
Doors The exception from latch-side maneuvering clearances is allowed only at acute care bedrooms, not throughout a hospital....
-
A. Door Width
Door Width....
-
1.4.4. Operational Requirements
Because movie theaters may comply with the requirement to provide captioning at all screenings of a digital movie produced or distributed with such features through the provision...