Search Results "Covered Multifamily Dwelling Unit (CBC 11A)"
-
1134A.7, Item 1
-
Shower Spray Unit and Water: ADA Standard Section 607.6
Section 607.5 covers the current ADA Standards for bathtub shower spray units and the water temperature of the spray units.
-
14. Common-use spaces and facilities
Accessible element or space ANSI A117.1 section APPLICATION 14. Common-use spaces and facilities (including swimming pools,...
-
1(2)(a)(i) Individual building test
(i) Individual building test. It is impractical to provide an accessible entrance served by an accessible route when the terrain of the site is such that: (A) the slopes of the...
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
11B-608.3 Grab bars
In residential dwelling units, grab bars shall not be required to be installed in showers located in bathing facilities provided that reinforcement has been installed in walls and located...
-
F233.2 Residential Dwelling Units Provided by HUD or Through Grant or Loan Programs Administered by HUD
Residential dwelling units subject to F233.2 shall not be required to comply with F233.3 or F233.4....
-
1136A.2 Switch and control heights
ETA Editor's Note Division V Sections 1137A through 1143A from California Building Code Chapter 11A, not adopted by Division of the State Architect - Access Compliance (DSA-AC), omitted...
-
1136A.2 Switch and control heights
ETA Editor's Note Division V Sections 1137A through 1143A from California Building Code Chapter 11A, are not adopted by the Division of the State Architect - Access Compliance (DSA-AC...
-
1136A.2 Switch and control heights
ETA Editor's Note Division V Sections 1137A through 1143A from California Building Code Chapter 11A are not adopted by the Division of the State Architect - Access Compliance (DSA-AC)...
-
11B-809.10 Toilet and bathing rooms
[See subsections ...]
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.8.1 Door Thresholds
Secondary exterior door thresholds, including sliding door tracks, shall be 3/4 inch (19.1 mm) high maximum with a 1:2 maximum slope.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10.7 Water closets
Water closets required by Section 11B-809.10 shall comply with this section.
-
11B-809.10.6.6 Controls
Controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.7 Shower enclosures
Doors and panels of shower enclosures shall comply with Section 11B-809.10.5.4.
-
11B-809.10.6.2 Slope
The slope of the shower floor shall be 1/2 inch (12.7 mm) per foot maximum in any direction and shall slope to a drain. The floor surfaces shall be of Carborundum, grit-faced tile or...
-
11B-809.10.5.2 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: 1. Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab...
-
1134A.7 Water closets
1134A.7 Water closets. Water closets in bathrooms or powder rooms required to be accessible shall comply with this section.
-
1134A.7 Water closets
Water closets in bathrooms or powder rooms required to be accessible shall comply with this section.