Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
Search Results "Compartment Depth"
Commonly Searched Documents
- 
    
  
  11B-608.8 Shower enclosures
  
- 
    
  
  11B-608.2.2.1 Clearance
  A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment.... 
- Inclusion Solutions Pakflatt® Franklin® Voting Booth
- Figure 611.4 Height of Laundry Compartment Opening – Drawing from the U.S. Access Board
- 
    
  
  11B-408.4.1 Car dimensions and doors
  Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum.... 
- 
    
  
  Forward Approach: ADA Standard Section 305.7.1
  Section 305.7.1 covers the current ADA Standards for the clear floor or ground space required for forward approach. 
- 
    
  
  Parallel Approach: ADA Standard Section 305.7.2
  Section 305.7.2 covers the current ADA Standards for the clear floor or ground space required for parallel approach. 
- 
    
  
  11B-305.7.1 Forward approach
  Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm).... 
- 
    
  
  11B-305.7.2 Parallel approach
  Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm).... 
- 
    
  
  11B-705.1.2.3 Islands or cut-through medians
  Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches... 
- Tork Elevation® Matic® Hand Towel Roll Dispenser with Intuition® Sensor, Black
- 
    
  
  5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
  The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface.... 
- 
    
  
  Bobrick Partition-Mounted Multi-Roll Toilet Tissue Dispenser (Serves 2 Compartments) B-386
  Requires the Premium User plan or above. (Login or upgrade your account!)
- Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
- Figure 608.5.1 Transfer Type Shower Compartment Control Location – Drawing from the U.S. Access Board
- 
    
  
  11B-705.1.2.4 Bus stops
  warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches (914 mm) minimum in depth... 
- 
    
  
  Transfer Platform: ADA Standard Section 1009.5.1
  Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width.... 
- 
    
  
  11B-1009.5.1 Transfer platform
  Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width.... 
- 
    
  
  A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
  Removable in-tub seats shall be 15 inches (380 mm) minimum and 16 inches (405 mm) maximum in depth. Removable in-tub seats shall be capable of secure placement.... 
- 
    
  
  Size: ADA Standard Section 1009.5.6
  Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum.... 
- 
    
  
  11B-1009.5.6 Size
  Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum.... 
- 
    
  
  Clearance Reduction: ADA Standard Section 306.3.4
  Section 306.3.4 covers the current ADA Standards for knee clearance width reduction. 
- 
    
  
  Conclusions
  Conclusions Design criteria based on the univariate analysis of abdomen depth is sufficient if all other clearance dimensions are unbounded (i.e., unrestricted) and abdomen depth is the... 
- 
    
  
  F222.2 Coat Hooks and Shelves
  Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with 803.5.... 