Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats....
Search Results "Compartment Depth"
Commonly Searched Documents
-
11B-608.8 Shower enclosures
-
11B-608.2.2.1 Clearance
A 36 inch (914 mm) wide minimum by 60 inch (1524 mm) long minimum clearance shall be provided adjacent to the open face of the shower compartment....
- Inclusion Solutions Pakflatt® Franklin® Voting Booth
- Figure 611.4 Height of Laundry Compartment Opening – Drawing from the U.S. Access Board
-
11B-408.4.1 Car dimensions and doors
Elevator cars shall provide a clear width 42 inches (1067 mm) minimum and a clear depth 54 inches (1372 mm) minimum....
-
Forward Approach: ADA Standard Section 305.7.1
Section 305.7.1 covers the current ADA Standards for the clear floor or ground space required for forward approach.
-
Parallel Approach: ADA Standard Section 305.7.2
Section 305.7.2 covers the current ADA Standards for the clear floor or ground space required for parallel approach.
-
11B-305.7.1 Forward approach
Alcoves shall be 36 inches (914 mm) wide minimum where the depth exceeds 24 inches (610 mm)....
-
11B-305.7.2 Parallel approach
Alcoves shall be 60 inches (1524 mm) wide minimum where the depth exceeds 15 inches (381 mm)....
-
11B-705.1.2.3 Islands or cut-through medians
Detectable warnings at pedestrian islands or cut-through medians shall be 36 inches (914 mm) minimum in depth extending the full width of the pedestrian path or cut-through less 2 inches...
- Tork Elevation® Matic® Hand Towel Roll Dispenser with Intuition® Sensor, Black
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
The transfer surface shall be located to provide options to transfer from a mobility device onto one short side (depth) and one long side (width) of the surface....
-
Bobrick Partition-Mounted Multi-Roll Toilet Tissue Dispenser (Serves 2 Compartments) B-386
Requires the Premium User plan or above. (Login or upgrade your account!)
- Figure 608.2.1 Transfer Type Shower Compartment Size and Clearance – Drawing from the U.S. Access Board
- Figure 608.5.1 Transfer Type Shower Compartment Control Location – Drawing from the U.S. Access Board
-
11B-705.1.2.4 Bus stops
warnings are provided at bus stop boarding and alighting areas, the detectable warnings shall extend the full width of the boarding/alighting area and shall be 36 inches (914 mm) minimum in depth...
-
Transfer Platform: ADA Standard Section 1009.5.1
Transfer platforms shall provide 19 inches (485 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
11B-1009.5.1 Transfer platform
Transfer platforms shall provide 19 inches (483 mm) minimum clear depth and 24 inches (610 mm) minimum clear width....
-
A MINIMUM HIGHEST POINT STANDARD OF 19 INCHES IS CONSISTENT WITH EXISTING ACCESSIBILITY STANDARDS
Removable in-tub seats shall be 15 inches (380 mm) minimum and 16 inches (405 mm) maximum in depth. Removable in-tub seats shall be capable of secure placement....
-
Size: ADA Standard Section 1009.5.6
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
Clearance Reduction: ADA Standard Section 306.3.4
Section 306.3.4 covers the current ADA Standards for knee clearance width reduction.
-
Conclusions
Conclusions Design criteria based on the univariate analysis of abdomen depth is sufficient if all other clearance dimensions are unbounded (i.e., unrestricted) and abdomen depth is the...
-
F222.2 Coat Hooks and Shelves
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with 803.5....